Mechanical installation

11.1

Surface mounted installation

The operator is mounted on either side of the door header with two available spindle locations,
LE Performance 95 mm and High performance 210 mm between hinges and outgoing shaft, de-
pending on type of doors.
The door is controlled with a push or pull arm system.
The illustrations also show how to route the cables. If there are sharp edges after drilling the cable
outlets, chamfer the edges to avoid damage to the cables.
Note! Consider all power wire entry locations and signaling wires before preparing back plate.
LE Performance 95 mm
A
C
A
B
C
11 /
3 /
40 mm
95 mm
1
16"
3
4"
1009728-en-9.0
B
135 mm
654 mm
14 mm
Issue 2021-02-24
High performance 210 mm
A
C
A
B
C
11 /
1 /
40 mm
210 mm
1
16"
8
4"
11 Mechanical installation
B
250 mm
613 mm
32 mm