18.4
Material specifications
Part
Pump hose *
Hose connection *
O-rings *
Dosing head
Rotor
Rollers on the rotor
Bearing cover
Housing upper part
Housing lower part
Cable threaded connectors
Metal parts (screws, etc.)
18.5
Electrical data
Design: 100 - 230 V ±10%, 50/60 Hz
18.6
Temperatures
Pump, fully assembled
Material
TPV or PUR
PVDF
PTFE
PA6 50 % GB
PPS 40 % GF
PA66
PC
PPE + 20 % GF
PPE + 20 % GF
PA6
A2
* wetted
Data
Nominal power, approx.
Current I
eff
Fuse
Fuses must have VDE, UL and CSA certification. E.g. series SPT, 1.6 A
supplied by Schurter Order. No. 0001.2506 according to IEC Publ. 127 -
2/3.
Data
Storage and transport temperature:
Ambient temperature in operation (power
end/drive and control):
Feed chemical temperature
Feed chemical temperature, briefly (5 min)
Technical data
Value Unit
45 W
0.45 ... 0.20 A
1.6 AT
Value Unit
- 10 ... +50 °C
-10 ... +45 °C
-10 ... +45 °C
+80 °C