13.
Place 2nd rotor half (5) on drive axle in dosing head with "This side
DOWN" surface being located first - the rollers must point towards
the recesses for the hydraulic connectors.
14.
Insert hose (4) in dosing head (5) and snap the two hydraulic con‐
nectors into place - round side in dosing head (5).
15.
Press the Clickwheel.
ð The rotor turns slowly and the following appears:
' Please wait!' .
The rotor stops and
16.
Re-insert 1st rotor half (3) - the surfaces of the two rotor halves
must be perfectly flush.
17.
Press the Clickwheel.
ð The rotor turns and the following appears:
'Please wait...' .
The rotor stops and
18.
Place bearing cover (1) on dosing head (6).
19.
Initially only loosely screw all 4 star screws (2) into dosing head (6).
20.
Manually tighten the 4 star screws (2).
21.
Press the Clickwheel.
'Run in tube?' appears.
ð
'Yes' / 'No'
[No] exits this macro.
22.
Selecting
23.
You can return to the continuous display by pressing the
If the dosing direction is also to be reversed, this can be
done by going to 'Settings è Dosing direction è ...'.
'Insert rotor again!' appears.
'Install Cover again!' appears.
Assembly
key.
25
Need help?
Do you have a question about the DULCO flex Control and is the answer not in the manual?
Questions and answers