switch "off". Set the timer to 120 min. This will switch off the light after 120 min. Then submit
the scenario and use the slider to activate it.
Question 12. How do I connect the controller to Pima Alarm System?
To connect the PIMA alarm system please do the following steps:
a. Log in the application and connect the alarm system - This can be done directly or through
a local network. If connecting directly - use the supplied cable, SA-232 converter and LCL-
11A adaptor. If you connect through a local network (LAN) use the net4pro-i network card.
b. Setting the serial port - Set the serial output use, regarding the connection to the MS
(monitoring station). The MS can be connected locally, using RS-232 cable, or remotely,
through the net4pro IP interface. It can use a home automation ("Smart home") or PIMA
proprietary protocol.
c. Log in the TouchWand application and open Units tab
PIMA alarm will be visible with the rest of devices in the Units section. There is no need for
pairing this unit. Just click on the Add unit button and select what kind of unit will be added
in the first field in this case PIMA sensor. Enter the rest of the data that is needed - type,
sensor name and zone and click on the Pair button.
Question 13. How do I connect the controller to RISCO Alarm System?
To connect the RISCO alarm system please do the following steps:
a. Log in the application and click on the Settings tab. RISCO settings can be added and edited
in the Settings tab under the Alarm sub menu.
b. Click on the Add Risco button. At this moment RISCO alarm system is not connected and
its status is Disabled not mounted.
c. Check Enable connection box.
d. Enter the IP address, port, password and upload a CSV file.
e. Click on the Save button.
Risco initial status is disarmed. To arm the alarm, click on the Arm button located below the
unit's status.
Question 14. What is a network healing? How do I use it?
Network healing (Network update) is the stage that takes place after all the end units have
been defined in the structure and after the functionality of each one has been tested. The
purpose of the procedure is to optimize the network communication. The duration of the
procedure varies from house to house pending number of units and size of the house (level,
floors etc...) and on average is about 5-20 minutes. While the procedure is being performed,
do not touch / change and / or physically and / or virtualize the endpoints for the success
and efficiency of the process.