BitWise System Setup

The Bitwise submenu is visible and available for editing only for users with technician
privileges!
The Bitwise settings can be added and edited in the Settings tab. You can check the server
status and client's connection by clicking on the Refresh as seen in the picture above.
When clicking the Enable connection checkbox, you will be able to connect with the
BitWise. In the Listen on IP field, enter the wanted IP address. By entering 0.0.0.0 the you
can access connections from any IP address. use 127.0.0.1 for local connections.
The controller creates a TCP server and listens to the clients on the port specified in the
settings (7443 in the example above).
BitWise AV Controllers are designed for customizable control of sub-systems at home or
any other location. In case of BC2 controller or BC1 controller, the client is the bitwise
controller itself and the max clients number in settings of our controller can be set as 1
client. In case of BC4 controller the max number of connections can be set by maximally
permitted simultaneous connections from your mobile devices to the Wanderfull
controller. The number of connections should be entered in the Max Connections field.
The module or script Device from BitWise is designed to enable Bitwise users to manage
the electrical circuits and scenarios defined in the Wanderfull controller.
To set up the script Device the user must configure controller's IP address, port and TCP
protocol. When the Wanderfull script Device is installed on BC4 controller for example, you
should also set the protocol to TCP GUI and set up SERIALPORT1 to GUI Two-Way (TCP).
Wanderfull Technical Manual