Devices that perform functions of the script must have the following name format (two
fields): <ID>_<NAME>
The device name can include only an ID number, without the name.
-
The ID number must be a real ID number corresponding to unit ID number in the
-
Wanderfull controller.
The unit ID and unit name must be separated by underscore character ("_").
-
The name field can contain any asci characters (there is no validation on name field).
-
Scenario functions
Persistent and user scenarios can be triggered only by an 'activation' function.
-
Dynamic scenarios can be only activated or deactivated. Dynamic scenario will not be
-
triggered by an 'activation' function.
Feedback
There are four kinds of feedback for each unit – value, text, state and name.
Value feedback: current value of the unit (in decimal percepts, in case of binary switch
-
it will be 0 or 255).
Text feedback: custom text label that is sent from the controller.
-
State feedback: 1 or 0 corresponding to unit current state.
-
Name feedback: current name of the unit from the Wanderfull controller.
-

KNX System Setup

The KNX submenu is visible and available for editing only for users with technician/installer
privileges!
In the Settings page, KNX tab, you can get the KNX status information.
-
There is an option for the controller to check its connection to the KNX IP router and to
-
ping units at specific intervals.
Wanderfull Technical Manual