2.5 CO Line Programming
[424] ISDN Configuration
Description
Assigns the configuration on ISDN port basis.
Selection
• Port number:
KX-TD816 – 01 through 04,
KX-TD1232 – 03 through 06, 09 through 12,
( =all ports)
• Point (point to point) / Multipoint (point to multipoint)
Default
All ports – Point
Programming
1.
Enter 424.
Display: Access Mode
2.
Press NEXT.
Display: Port No?
3.
Enter a port number.
To enter a first port number, you can also press NEXT.
Display example: #03:Point
4.
Keep pressing SELECT until the desired selection is displayed.
5.
Press STORE.
6.
To programme another port, press NEXT or PREV, or SELECT and the desired port
number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
• In case of KX-TD1232, port numbers 01 through 06 are for the Master System and 07
through 12 are for the Slave, if available.
• If one equipment is connected to the ISDN port, select "Point." If multiple equipment are
connected, select "Multipoint."
• To assign all ports to one selection, press the
the contents programmed for a first port.
• After this assignment, you should reset the system so that this assignment is effective.
176
key at step 3. In this case, the display shows
General Programming