FC 300 Design Guide
Description
Pos
Product group
1-3
Drive series
4-6
Power rating
8-10 0.25-560 kW
Phases
11
Mains voltage
11-
12
Enclosure
13-
15
RFI filter
16-
17
Brake
18
Display
19
Coating PCB
20
Mains option
21
Adaptation
22
Adaptation
23
Software release
24-
27
Software language
28
1): FC 301/ A1 enclosure only
2): Power sizes ≥ 90 kW only
3) US Market only
4): Power sizes ≥ 11 kW only
Not all choices/options are available for each FC 301/FC 302 variant. To
verify if the appropriate version is available, please consult the Drive
Configurator on the Internet.
Possible choice
FC 30x
FC 301
FC 302
Three phases (T)
T 2: 200-240 V AC
T 4: 380-480 V AC
T 5: 380-500 V AC
T 6: 525-600 V AC
T 7: 525-690 V AC
E00: IP00/ Chassis
C00: IP00/ Chassis Corrosion resistant
E0D: IP00/ Chassis, D enclosure
C0D: IP00/ Chassis Corrosion resist-
ant, D enclosure
E20: IP20
E2D: IP 21/NEMA Type 1, D1 enclo-
sure
E54: IP 54/NEMA Type 12
E55: IP 55/NEMA Type 12
E5D: IP00/ Chassis, D enclosure
P20: IP20 (with back plate)
P21: IP21/ NEMA Type 1 (with back
plate)
P55: IP55/ NEMA Type 12 (with back
plate)
1)
Z20: IP 20
E66: IP 66
H1: RFI filter class A1/B1
H2: No RFI filter, observes class A2
1)
H3: RFI filter class A1/B1
2)
H4: RFI filter class A1
1)
H6: RFI filter Maritime use
HX: No filter (600 V only)
B: Brake chopper included
X: No brake chopper included
1)
T: Safe Stop No brake
1)
U: Safe stop brake chopper
G: Graphical Local Control Panel (LCP)
N: Numerical Local Control Panel (LCP)
X: No Local Control Panel
C: Coated PCB
X. No coated PCB
X: No mains option
1: Mains disconnect
3: Mains disconnect and Fuse
3)
5: Mains disconnect, Fuse and Load
3, 4)
sharing
3)
7: Fuse
8: Mains disconnect and Load shar-
ing
4)
A: Fuse and Load sharing
3, 4)
4)
D: Load sharing
Reserved
Reserved
Actual software
MG.33.BA.02 - VLT
®
is a registered Danfoss trademark
Description
Pos
Possible choice
A options
29-
AX: No A option
30
A0: MCA 101 Profibus DP V1 (stand-
ard)
A1: MCA 101 Profibus DP V1 (with top-
entry)
A4: MCA 104 DeviceNet (standard)
A4: MCA 104 DeviceNet (with top-en-
try)
A6: MCA 105 CANOpen (standard)
A6: MCA 105 CANOpen (with top-en-
try)
AN: MCA 121 Ethernet IP
AT: MCA 113 Profibus converter
VLT3000
AY: MCA 123 Ethernet PowerLink
B options
31-
BX: No option
32
BK: MCB 101 General purpose I/O op-
tion
BR: MCB 102 Encoder option
BU: MCB 103 Resolver option
BP: MCB 105 Relay option
BZ: MCB 108 Safety PLC Interface
B2: MCB 112 PTC Thermistor Card
C0 options
33-
CX: No option
34
C4: MCO 305, Programmable Motion
Controller.
C1 options
35
X: No option
R: MCB 113 Ext. Relay Card
C option software
36-
XX: Standard controller
37
10: MCO 350 Synchronizing control
11: MCO 351 Positioning control
12: MCO 352 Center winder
D options
38-
DX: No option
39
D0: DC back-up