4. FC 300 Selection
Mains Supply 3 x 525- 690 VAC
FC 302
High/ Normal Load*
Output current
4
Max. input current
* High overload = 160% torque during 60 s, Normal overload = 110% torque during 60 s
1) For type of fuse see section
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to variety in voltage and cable
conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the frequency
converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30W to the losses. (Though
typical only 4W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/-5%).
64
HO
Typical Shaft output at 550
315
V [kW]
Typical Shaft output at 575
400
V [HP]
Typical Shaft output at 690
355
V [kW]
Enclosure IP21, 54
Enclosure IP00
Continuous
395
(at 550 V) [A]
Intermittent (60 sec over-
load)
593
(at 550 V) [A]
Continuous
380
(at 575/ 690 V) [A]
Intermittent (60 sec over-
load)
570
(at 575/ 690 V) [A]
Continuous KVA
376
(at 550 V) [KVA]
Continuous KVA
378
(at 575 V) [KVA]
Continuous KVA
454
(at 690 V) [KVA]
Continuous
381
(at 550 V ) [A]
Continuous
366
(at 575 V) [A]
Continuous
366
(at 690 V) [A]
Max. cable size, mains mo-
tor and load share [mm
2
(AWG)]
Max. cable size, brake
[mm
2
(AWG)]
1
Max. pre-fuses [A]
Estimated power loss
5383
at rated max. load [W]
4)
Weight,
enclosure IP21, IP 54 [kg]
Weight,
enclosure IP00 [kg]
Efficiency
4)
Fuses.
MG.33.BA.02 - VLT
P355
P400
NO
HO
NO
355
315
400
450
400
500
450
400
500
E1
E1
E2
E2
470
429
523
517
644
575
450
410
500
495
615
550
448
409
498
448
408
498
538
490
598
453
413
504
434
395
482
434
395
482
4x240 (4x500 mcm)
2 x 185 (2 x 350 mcm)
700
700
6449
5818
7249
263
263
221
221
0.98
0.98
®
is a registered Danfoss trademark
FC 300 Design Guide
P500
P560
HO
NO
HO
NO
400
450
450
500
500
600
600
650
500
560
560
630
E1
E1
E2
E2
523
596
596
630
785
656
894
693
500
570
570
630
750
627
855
693
498
568
568
600
498
568
568
627
598
681
681
753
504
574
574
607
482
549
549
607
482
549
549
607
900
900
7671
8727
8715
9673
272
313
236
277
0.98
0.98