3. Introduction to FC 300

3.4.2. EMC test results

The following test results have been obtained using a system with a frequency converter (with options if relevant),
a screened control cable, a control box with potentiometer, as well as a motor and motor screened cable.
RFI filter type
3
Setup
H1
FC301:
FC302:
H2
FC301/ 302:
H3
FC301:
H4
FC302
Hx
FC302
Table 3.1: EMC Test Results (Emission, Immunity)
HX, H1, H2 or H3 is defined in the type code pos. 16 - 17 for EMC filters
HX - No EMC filters build in the frequency converter (600 V units only)
H1 - Integrated EMC filter. Fulfil Class A1/B
H2 - No additional EMC filter. Fulfil Class A2
H3 - Integrated EMC filter. Fulfil class A1/B (Enclosure type A1 only)
H4 - Integrated EMC filter. Fulfil class A1
3.4.3. Emission Requirements
According to the EMC product standard for adjustable speed frequency converters EN/IEC61800-3:2004 the EMC requirements depend on the intended
use of the frequency converter. Four categories are defined in the EMC product standard. The definitions of the four categories together with the
requirements for mains line conducted emissions are given in the table below:
Category
Definition
C1
frequency converters installed in the first environment (home and office) with a supply
voltage less than 1000 V.
C2
frequency converters installed in the first environment (home and office) with a supply
voltage less than 1000 V which are neither plug-in nor movable and are intended to be
installed and commissioned by a professional.
C3
frequency converters installed in the second environment (industrial) with a supply
voltage lower than 1000 V.
C4
frequency converters installed in the second environment with a supply voltage above
1000 V and rated current above 400 A or intended for use in complex systems.
38
Industrial environment
EN 55011
Class A2
0-3.7 kW 200-240 V
75 m
0-22 kW 380-480 V
75 m
0-37 kW 200-240 V
150 m
0-75 kW 380-480 V
150 m
0-3.7 kW 200-240 V
5 m
5.5-37 kW 200-240 V
25 m
0-7.5 kW 380-480 V
5 m
11-75 kW 380-480 V
25 m
90-400 kW 380-480 V
50 m
75-500 kW 525-600 V
150 m
0-1.5 kW 200-240 V
50 m
0-1.5 kW 380-480 V
50 m
90-400 kW 380-480 V
150 m
75-315 kW 525-600 V
150 m
0.75-7.5 kW 525-600
V
MG.33.BA.02 - VLT
Conducted emission
Housing,
trades and
light indus-
tries
EN 55011
EN 55011
Class A1
Class B
50 m
10 m
50 m
10 m
150 m
50 m
150 m
50 m
No
No
No
No
No
No
No
No
No
No
No
No
25 m
2.5 m
25 m
2.5 m
150 m
No
150 m
No
-
-
-
®
is a registered Danfoss trademark
FC 300 Design Guide
Radiated emission
Industrial
Housing, trades
environment
and light indus-
tries
EN 55011
EN 55011 Class
Class A1
B
Yes
No
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
No
Yes
No
Yes
No
No
No
-
-
Conducted emission requirement accord-
ing to the limits given in EN55011
Class B
Class A Group 1
Class A Group 2
No limit line. An EMC plan should be made.