Failure Indications; Unexpected Use Of (Address) Failure Messages - HP 400 Series Servicing Manual

Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

3 Hex LSDs
EEC - F16
4.9.3

Failure Indications

As the self-test progresses, the LEDs display the current state. At the end of the test,
a power-up with no errors is indicated by all LEDs turned off and by immediate entry
into the boot scanner.
If a failure occurred during the self-tests, then that failure is indicated on the LEDs at
the end of the tests. If there was more than one failure, the highest priority failure is
indicated on the LEDs.
4-40
Fault Isolation
Table 4-6.

Unexpected Use of (address) Failure Messages

Unexpected Event
FFA
Bus error
FF4
Address error
FFE
Illegal instruction
FE8
Zero by zero trap
FE2
Check trap
FDC
TRAPV trap
FD6
Privilege violation
FCA
1010 Op. Code
FC4
1111 Op. Code
FBE
Interrupt Level 1 (keyboard)
FB8
Interrupt Level 2 (not used)
FB2
Interrupt Level 3
FAC
Interrupt Level 4
FA6
Interrupt Level 5
FA0
Interrupt Level 6
F9A
Interrupt Level 7 (Reset from keyboard)
F3A-F94
CPU traps
F34
Reset from keyboard
F2E
Keyboard timeout (fast handshake)
F28
Battery backup interrupt
F22
Non-maskable interrupt from the backplane
F1C
Spurious interrupt
Vectored interrupt
EE6
Format error, co-processor violation, or unknown
EE0
Co-processor exception vectors