HP 400 Series Servicing Manual page 146

Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

10. To find out what ce.utilities tests are already in the HP-UX operating system,
11. If you want to run a test that is not already in HP-UX, you must first copy the test
Information on each CE.utility test may be found as follows:
• FLOAT type the following commands and a help file appears on the screen.
• VME: type the following command and a readme file appears on the screen.
Refer to the System Support Tape User's Guide and the Series 300 Test Tools Manual
for detailed information on running the CE.utilities.
4-76
Fault Isolation
type these commands:
cd /usr/diag/CE.utilities < Return >
ls < Return >
from the tape to the HP-UX file system. A new directory, /usr/CE.utilities, is
automatically created and the files from the tape are copied into it. Type the fol-
lowing command, where test is one of the eight test files you want to copy from the
tape to the file system:
lifcp -r /dev/drive:test - | cpio -icdvxm < Return >
CRTADJ: refer to System Support Tape User's Guide.
CS/80: refer to the Series 300 Test Tools Manual.
NOTICE:
If the CS/80 test is run in single user mode, the sys-
tem halts when the exerciser is stopped. You must
reboot HP-UX to continue.
cd /usr/CE.utilities/Floatcard < Return >
./help < Return >
SFT refer to the Series 300 Test Tools Manual.
more vme_README < Return >
ECC: type the following commands for information on setting up and execu-
ting the ECC tests.
cd /etc
man ecclogger < Return >
end of procedure

Advertisement