You can troubleshoot a Domain Compatible mode system that has display problems
by connecting a terminal to the system SIO line. This appendix provides procedures to
connect the standard field terminal or another node to the system's SIO line.
D.1
Using a Field Terminal
The data terminal currently available for field use is a specially modified IXO model
TC301. This device is battery powered with a 1-line, 16-character LCD display. The
terminal communicates at 300 baud only, and is configured as a DCE device. It plugs
into the system, and its attached cable needs no adapters. Use Procedure D-1 to activate
the field terminal.
Procedure D-1. Activating a Field Terminal
1. Press the ON/OFF key. The terminal displays the message
2. Press the NO key. The terminal displays the message
3. Press the PHONE key. The terminal displays the message
HI, IXO ACCESS CENTER?
MANUAL, FULL
LOGGING ON
The terminal displays the online mode indicator.
Appendix D
Connecting Terminals
to Domain/OS Systems
Connecting Terminals
D-1