Functional Diagrams For Condition Monitoring - ABB RELION 615 Series Applications Manual

Generator and interconnection protection
Hide thumbs Also See for RELION 615 Series:
Table of Contents

Advertisement

1MRS758272 B
OR
B1
MNSPTOC1_OPERATE
B2
MNSPTOC2_OPERATE
OR
B1
PHPTUV1_OPERATE
B2
PHPTUV2_OPERATE
OR
B1
PHPTOV1_OPERATE
B2
PHPTOV2_OPERATE
OR6
B1
FRPFRQ1_OPERATE
B2
FRPFRQ2_OPERATE
B3
FRPFRQ3_OPERATE
B4
FRPFRQ4_OPERATE
B5
B6
OR6
B1
ROVPTOV1_OPERATE
B2
ROVPTOV2_OPERATE
B3
NSPTOV1_OPERATE
B4
NSPTOV2_OPERATE
B5
PSPTUV1_OPERATE
B6
PSPTUV2_OPERATE
OR6
B1
DUPPDPR1_OPERATE
B2
DUPPDPR2_OPERATE
B3
DOPPDPR1_OPERATE
B4
DOPPDPR2_OPERATE
B5
DOPPDPR3_OPERATE
B6
OR6
B1
ARCSARC1_ARC_FLT_DET
B2
ARCSARC2_ARC_FLT_DET
B3
ARCSARC3_ARC_FLT_DET
B4
B5
B6
GUID-33594DA5-23FE-426F-B57F-83319BAD81B7 V2 EN
Figure 100:
Disturbance recorder
3.4.3.3
REG615
Application Manual
B1
PHIPTOC1_OPERATE
B2
PHHPTOC1_OPERATE
B3
PHLPTOC1_OPERATE
B4
PHPVOC1_OPERATE
B5
B6
O
B1
EFHPTOC1_OPERATE
B2
DEFLPDEF1_OPERATE
B3
DEFLPDEF2_OPERATE
B4
DEFHPDEF1_OPERATE
O
B5
B6
O
O
O
O
O

Functional diagrams for condition monitoring

The fuse failure supervision function SEQSPVC1 detects failures in the voltage
measurement circuits. Failures, such as an open MCB, raise an alarm.
X110_BI7_CB_CLOSED
X110_BI1_TERMINAL_VT_MCB_OPEN
GUID-7B1E78AE-386C-4798-B341-238067D0BA37 V2 EN
Figure 101:
Fuse failure supervision function
Circuit-breaker condition monitoring SSCBR1 supervises the switch status based on
the connected binary input information and the measured current levels. SSCBR1
introduces various supervision methods.
Set the parameters for SSCBR1 properly.
REG615 standard configurations
OR6
O
PHLPTOC1_START
PHHPTOC1_START
PHIPTOC1_START
PHPVOC1_START
DEFLPDEF1_START
DEFLPDEF2_START
DEFHPDEF1_START
EFHPTOC1_START
OR6
MNSPTOC1_START
MNSPTOC2_START
O
PHPTUV1_START
PHPTUV2_START
H3EFPSEF1_START
PHPTOV1_START
PHPTOV2_START
FRPFRQ1_START
FRPFRQ2_START
FRPFRQ3_START
FRPFRQ4_START
OEPVPH1_START
UZPDIS1_START
UEXPDIS1_START
ROVPTOV1_START
ROVPTOV2_START
NSPTOV1_START
NSPTOV2_START
PSPTUV1_START
PSPTUV2_START
DUPPDPR1_START
DUPPDPR2_START
DOPPDPR1_START
DOPPDPR2_START
DOPPDPR3_START
T2PTTR1_START
CCBRBRF1_TRRET
CCBRBRF1_TRBU
H3EFPSEF1_OPERATE
OEPVPH1_OPERATE
UZPDIS1_OPERATE
UEXPDIS1_OPERATE
INRPHAR1_BLK2H
T2PTTR1_OPERATE
SEQSPVC1_FUSEF_3PH
SEQSPVC1_FUSEF_U
X130_BI1_EXT_TRIP1
X130_BI2_EXT_TRIP2
X130_BI4_FIELD_EXCITATION_OPEN
X110_BI7_CB_CLOSED
X110_BI8_CB_OPENED
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
SEQSPVC1
BLOCK
CB_CLOSED
DISCON_OPEN
MINCB_OPEN
Section 3
RDRE
RDRE1
C1
TRIGGERED
DISTURB_RECORD_TRIGGERED
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
FUSEF_3PH
SEQSPVC1_FUSEF_3PH
FUSEF_U
SEQSPVC1_FUSEF_U
87