Functional Diagrams For Condition Monitoring - ABB RELION 615 Series Applications Manual

Generator and interconnection protection
Hide thumbs Also See for RELION 615 Series:
Table of Contents

Advertisement

Section 3
REG615 standard configurations
B1
PHIPTOC1_OPERATE
B2
PHHPTOC1_OPERATE
B3
PHLPTOC1_OPERATE
B4
PHPVOC1_OPERATE
B5
B6
B1
EFHPTOC1_OPERATE
B2
DEFLPDEF1_OPERATE
B3
DEFLPDEF2_OPERATE
B4
DEFHPDEF1_OPERATE
B5
B6
B1
MNSPTOC1_OPERATE
B2
MNSPTOC2_OPERATE
B1
DOPPDPR1_OPERATE
B2
DOPPDPR2_OPERATE
B3
DUPPDPR1_OPERATE
B4
DUPPDPR2_OPERATE
B5
B6
B1
ROVPTOV1_OPERATE
B2
ROVPTOV2_OPERATE
B1
FRPFRQ1_OPERATE
B2
FRPFRQ2_OPERATE
B3
FRPFRQ3_OPERATE
B4
FRPFRQ4_OPERATE
B5
B6
B1
ARCSARC1_ARC_FLT_DET
B2
ARCSARC2_ARC_FLT_DET
B3
ARCSARC3_ARC_FLT_DET
B4
B5
B6
GUID-A671BF3D-4779-4554-9CB8-58C795EF109A V2 EN
Figure 158:
Disturbance recorder
3.5.3.3
118
OR6
O
OR6
O
OR
O
OR6
O
OR
O
X130_BI4_FIELD_EXCITATION_OPEN
OR6
O
OR6
O

Functional diagrams for condition monitoring

The fuse failure supervision function SEQSPVC1 detects failures in the voltage
measurement circuits. Failures, such as an open MCB, raise an alarm.
X110_BI7_CB_CLOSED
X110_BI1_TERMINAL_VT_MCB_OPEN
GUID-9EA94DB3-DEAA-4BAB-864D-46A505B8520C V2 EN
Figure 159:
Fuse failure supervision function
Circuit-breaker condition monitoring SSCBR1 supervises the switch status based on
the connected binary input information and the measured current levels. SSCBR1
introduces various supervision methods.
C1
PHLPTOC1_START
C2
PHHPTOC1_START
C3
PHIPTOC1_START
C4
PHPVOC1_START
C5
DEFLPDEF1_START
C6
DEFLPDEF2_START
C7
DEFHPDEF1_START
C8
EFHPTOC1_START
C9
MNSPTOC1_START
C10
MNSPTOC2_START
C11
DOPPDPR1_START
C12
DOPPDPR2_START
C13
DUPPDPR1_START
C14
DUPPDPR2_START
C15
OEPVPH1_START
C16
UEXPDIS1_START
C17
ROVPTOV1_START
C18
ROVPTOV2_START
C19
FRPFRQ1_START
C20
FRPFRQ2_START
C21
FRPFRQ3_START
C22
FRPFRQ4_START
C23
T2PTTR1_START
C24
C25
C26
C27
C28
OEPVPH1_OPERATE
C29
UEXPDIS1_OPERATE
C30
C31
C32
MPDIF1_OPR_LS
C33
MPDIF1_OPR_HS
C34
MPDIF1_INT_BLKD
C35
T2PTTR1_OPERATE
C36
CCBRBRF1_TRRET
C37
CCBRBRF1_TRBU
C38
INRPHAR1_BLK2H
C39
SEQSPVC1_FUSEF_U
C40
X130_BI1_EXT_TRIP1
C41
X130_BI2_EXT_TRIP2
C42
C43
X110_BI7_CB_CLOSED
C44
X110_BI8_CB_OPENED
C45
C46
ARCSARC1_OPERATE
C47
ARCSARC2_OPERATE
C48
ARCSARC3_OPERATE
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
SEQSPVC1
BLOCK
CB_CLOSED
DISCON_OPEN
MINCB_OPEN
1MRS758272 B
RDRE
RDRE1
TRIGGERED
DISTURB_RECORD_TRIGGERED
FUSEF_3PH
FUSEF_U
SEQSPVC1_FUSEF_U
Application Manual
REG615