Functional Diagrams For Condition Monitoring - ABB RELION 615 Series Applications Manual

Generator and interconnection protection
Hide thumbs Also See for RELION 615 Series:
Table of Contents

Advertisement

Section 3
REG615 standard configurations
PHIPTOC1_OPERATE
DPHHPDOC1_OPERATE
DPHLPDOC1_OPERATE
DPHLPDOC2_OPERATE
B1
PHPTOV1_OPERATE
B2
PHPTOV2_OPERATE
NSPTOC1_OPERATE
NSPTOC2_OPERATE
PHPTUV1_OPERATE
PHPTUV2_OPERATE
B1
ROVPTOV1_OPERATE
B2
ROVPTOV2_OPERATE
B3
NSPTOV1_OPERATE
B4
NSPTOV2_OPERATE
B5
PSPTUV1_OPERATE
B6
PSPTUV2_OPERATE
B1
FRPFRQ1_OPERATE
B2
FRPFRQ2_OPERATE
B3
FRPFRQ3_OPERATE
B4
FRPFRQ4_OPERATE
B5
B6
B1
DOPPDPR1_OPERATE
B2
DOPPDPR2_OPERATE
LVRTPTUV1_OPERATE
LVRTPTUV2_OPERATE
LVRTPTUV3_OPERATE
B1
ARCSARC1_ARC_FLT_DET
B2
ARCSARC2_ARC_FLT_DET
B3
ARCSARC3_ARC_FLT_DET
B4
B5
B6
GUID-9F69A3C5-B053-4A3C-B5F5-8E9AAE223BF9 V2 EN
Figure 37:
Disturbance recorder
3.3.3.3
54
OR6
B1
B2
B3
B4
B5
B6
OR
O
OR
B1
B2
OR
B1
B2
OR6
O
OR6
O
OR
O
OR6
B1
B2
B3
B4
B5
B6
OR6
O

Functional diagrams for condition monitoring

Failures in the current measuring circuits are detected by CCSPVC1. When a failure
is detected, it is used to block current protection functions which measure the
calculated sequence component currents or residual current to avoid unnecessary
operation.
GUID-33EA9503-3A28-45FB-BDC0-67D86B94C792 V2 EN
Figure 38:
Current circuit supervision function
The fuse failure supervision function SEQSPVC1 detects failures in the voltage
measurement circuits. Failures, such as an open MCB, raise an alarm.
O
PHIPTOC1_START
DPHLPDOC1_START
DPHLPDOC2_START
DPHHPDOC1_START
EFHPTOC1_START
NSPTOC1_START
NSPTOC2_START
PHPTOV1_START
PHPTOV2_START
PHPTUV1_START
PHPTUV2_START
ROVPTOV1_START
ROVPTOV2_START
NSPTOV1_START
O
NSPTOV2_START
PSPTUV1_START
PSPTUV2_START
FRPFRQ1_START
FRPFRQ2_START
FRPFRQ3_START
FRPFRQ4_START
T1PTTR1_START
O
DOPPDPR1_START
DOPPDPR2_START
DQPTUV1_START
LVRTPTUV1_START
LVRTPTUV2_START
LVRTPTUV3_START
EFHPTOC1_OPERATE
T1PTTR1_OPERATE
DQPTUV1_OPERATE
VVSPPAM1_OPERATE
ARCSARC1_OPERATE
ARCSARC2_OPERATE
ARCSARC3_OPERATE
SEQSPVC1_FUSEF_U
CCSPVC1_FAIL
INRPHAR1_BLK2H
VVSPPAM1_INT_BLKD
CCBRBRF1_TRRET
CCBRBRF1_TRBU
X110_BI7_CB_CLOSED
X110_BI8_CB_OPENED
O
CCSPVC1(MCS 3I(
BLOCK
FAIL
ALARM
RDRE
RDRE1
C1
TRIGGERED
DISTURB_RECORD_TRIGGERED
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C60
C61
C62
C63
C64
CCSPVC1_FAIL
CCSPVC1_ALARM
Application Manual
1MRS758272 B
REG615

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion reg615

Table of Contents