Operating Instruction EXTRAmatic 9040
|
5 Operation

5.2 User programs

5.2 User programs

5.2.1 Level measurement series

▶ Switch the on/off switch to "I" (ON).
After switch-on, the unit automatically completes a series of level sensor measure‐
ments and cleans each individual extraction channel in turn at the most powerful
extraction level.
Once this is complete, the extractor unit is in automatic mode ('automatic mode' LED
is on).
The extractor unit automatically detects whether there are one, two or three external
control panels connected up to it.
The display shows the software and hardware version.
Anzeige Benutzer
SW 3.2 HW 1.2

5.2.2 Automatic mode

This is recommended for normal operation.
▶ Press the button.
This switches from "Continuous" to "Automatic" mode.
In automatic mode, extraction only starts when at least one of the connected devices
(e.g. K5 or K12 unit) is in operation.

5.2.3 Continuous mode

This is suitable for use with tools that have no electrical connection (turbine systems
for instance).
Note
If the item generating dust does not deliver an electric signal and there is no external
operating panel present, a foot switch can be used to switch to continuous mode
(A 5.5).
▶ Press the button.
This switches (manually) from "Automatic" to "Continuous" mode.
35/62