Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 Table of contents Table of contents 1 User instructions............................. 5 2 Safety ................................6 2.1 Infection hazard ............................. 2.2 Air embolism and skin emphysema ....................... 2.3 Allergic reactions ...........................
Page 4
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 Table of contents 7.3.2 Manual disinfection of the interior ..................... 21 7.3.3 Mechanical disinfection of the exterior and interior..............21 7.4 Care products and systems - Servicing ....................21 7.5 Packaging ..............................
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 1 User instructions 1 User instructions Dear User Congratulations on purchasing this KaVo quality product. By following the instructions below you will be able to work smoothly, economically and safely.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 2 Safety | 2.1 Infection hazard 2 Safety The instructions for use are a component of the product and must be read carefully prior to use and be accessible at all times.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 2 Safety | 2.5 Accessories and combination with other equipment ▶ The device should be cleaned, serviced and stored in a dry location, according to instructions, if it will not be used for a longer period.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 2 Safety | 2.7 Service and repair ▶ Clean the suction hoses of the treatment centre after every application. - For this purpose, aspirate approx. 200 ml of water with the tube to be cleaned.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 3 Product description | 3.3 Scope of delivery 3.3 Scope of delivery The set consists of: ① 1 x PROPHYflex 3 – 2018 for Sirona connection ②...
▪ Small water volume = little cleaning efficiency and a lot of dust. ▪ Large water volume = great cleaning efficiency and less dust. Note As the PROPHYflex 3 - 2018 SIRONA does not require any light or airspray, these functions will need to be deleted. 4.2 Check the pressure...
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 4 Start up and shut down | 4.3 Check O-rings ▶ Attach the test manometer for Sirona Test star to the Sirona coupling and check the following pressures: ð...
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.1 Attaching the medical device 5 Operation Note At the beginning of each workday, the water-conducting systems should be rinsed for at least 2 min. without the medical device being attached.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.4 Inserting the cannula Adjusting the powder volume The flow rate of the powder can be adjusted by changing the P-nozzle ①. ▪ P-nozzle G = larger powder volume ▪...
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder ®...
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder 5.6.1 PROPHYflex powder CAUTION Hazard from the use of PROPHYflex on the gingiva.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder ① Sodium bicarbonate (PROPHYflex ② Calcium carbonate (PROPHYpearls®): Powder): working angle 60° to 90°...
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 6 Troubleshooting | 6.1 Cleaning a blocked cannula 6 Troubleshooting Preventive measures After each treatment and before each sterilisation, unscrew the powder container in an anti-clockwise direction and replace it with a clean powder container. Mount the PRO- PHYflex on the Sirona coupling and blow through the air and water channels.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 7 Reprocessing steps in accordance with ISO 17664 | 7.1 Preparation at the site of use 7 Reprocessing steps in accordance with ISO 17664 7.1 Preparation at the site of use WARNING Hazard from incorrectly reprocessed products.
Validated internal cleaning (removal of residual protein) can be accomplished with KaVo CLEANspray and KaVo DRYspray. ▶ Cover the medical device with the KaVo CLEANpac bag, and place it on the cor- responding servicing adapter. Press the spray button three times for 2 seconds each time.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 7 Reprocessing steps in accordance with ISO 17664 | 7.4 Care products and systems - Servicing 7.3.1 Manual disinfection of the the exterior KaVo recommends the following products based on compatibility of the materials. The microbiological efficacy must be ensured by the disinfectant manufacturer.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 7 Reprocessing steps in accordance with ISO 17664 | 7.5 Packaging 7.5 Packaging Note The sterilisation bag must be large enough for the instrument so that the bag is not stretched.
Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 9 Terms and conditions of warranty 9 Terms and conditions of warranty The following warranty conditions apply to this KaVo medical device: KaVo provides the end customer with a warranty of proper function and guarantees...
Need help?
Do you have a question about the PROPHYflex 3 and is the answer not in the manual?
Questions and answers