KaVo PROPHYflex 3 Instructions For Use Manual

KaVo PROPHYflex 3 Instructions For Use Manual

2018 for sirona connection
Hide thumbs Also See for PROPHYflex 3:

Advertisement

Instructions for use
PROPHYflex 3 - 2018 for Sirona connection -
1.006.9920, - 1.006.9927

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PROPHYflex 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for KaVo PROPHYflex 3

  • Page 1 Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH Kaltenbach & Voigt GmbH Bismarckring 39 Bismarckring 39 D-88400 Biberach D-88400 Biberach Phone +49 (0) 7351 56-0 www.kavo.com Fax +49 (0) 7351 56-1488...
  • Page 3: Table Of Contents

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 Table of contents Table of contents 1 User instructions............................. 5 2 Safety ................................6 2.1 Infection hazard ............................. 2.2 Air embolism and skin emphysema ....................... 2.3 Allergic reactions ...........................
  • Page 4 Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 Table of contents 7.3.2 Manual disinfection of the interior ..................... 21 7.3.3 Mechanical disinfection of the exterior and interior..............21 7.4 Care products and systems - Servicing ....................21 7.5 Packaging ..............................
  • Page 5: User Instructions

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 1 User instructions 1 User instructions Dear User Congratulations on purchasing this KaVo quality product. By following the instructions below you will be able to work smoothly, economically and safely.
  • Page 6: Safety

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 2 Safety | 2.1 Infection hazard 2 Safety The instructions for use are a component of the product and must be read carefully prior to use and be accessible at all times.
  • Page 7: Accessories And Combination With Other Equipment

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 2 Safety | 2.5 Accessories and combination with other equipment ▶ The device should be cleaned, serviced and stored in a dry location, according to instructions, if it will not be used for a longer period.
  • Page 8: Service And Repair

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 2 Safety | 2.7 Service and repair ▶ Clean the suction hoses of the treatment centre after every application. - For this purpose, aspirate approx. 200 ml of water with the tube to be cleaned.
  • Page 9: Product Description

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 3 Product description | 3.1 Purpose – Intended use 3 Product description PROPHYflex 3 - 2018 SIRONA black Mat. no. 1.006.9920 PROPHYflex 3 - 2018 SIRONA violet Mat. no. 1.006.9927 3.1 Purpose –...
  • Page 10: Scope Of Delivery

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 3 Product description | 3.3 Scope of delivery 3.3 Scope of delivery The set consists of: ① 1 x PROPHYflex 3 – 2018 for Sirona connection ②...
  • Page 11: Start Up And Shut Down

    ▪ Small water volume = little cleaning efficiency and a lot of dust. ▪ Large water volume = great cleaning efficiency and less dust. Note As the PROPHYflex 3 - 2018 SIRONA does not require any light or airspray, these functions will need to be deleted. 4.2 Check the pressure...
  • Page 12: Check O-Rings

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 4 Start up and shut down | 4.3 Check O-rings ▶ Attach the test manometer for Sirona Test star to the Sirona coupling and check the following pressures: ð...
  • Page 13: Operation

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.1 Attaching the medical device 5 Operation Note At the beginning of each workday, the water-conducting systems should be rinsed for at least 2 min. without the medical device being attached.
  • Page 14: Inserting The Cannula

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.4 Inserting the cannula Adjusting the powder volume The flow rate of the powder can be adjusted by changing the P-nozzle ①. ▪ P-nozzle G = larger powder volume ▪...
  • Page 15: Instructions For Use For Prophyflex Powder, Prophypearls®, Prophyflex Perio Powder

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder ®...
  • Page 16: Prophyflex Powder

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder 5.6.1 PROPHYflex powder CAUTION Hazard from the use of PROPHYflex on the gingiva.
  • Page 17: Prophyflex Perio Powder

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 5 Operation | 5.6 Instructions for use for PROPHYflex Powder, PROPHYpearls®, PROPHYflex Perio Powder ① Sodium bicarbonate (PROPHYflex ② Calcium carbonate (PROPHYpearls®): Powder): working angle 60° to 90°...
  • Page 18: Troubleshooting

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 6 Troubleshooting | 6.1 Cleaning a blocked cannula 6 Troubleshooting Preventive measures After each treatment and before each sterilisation, unscrew the powder container in an anti-clockwise direction and replace it with a clean powder container. Mount the PRO- PHYflex on the Sirona coupling and blow through the air and water channels.
  • Page 19: Reprocessing Steps In Accordance With Iso 17664

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 7 Reprocessing steps in accordance with ISO 17664 | 7.1 Preparation at the site of use 7 Reprocessing steps in accordance with ISO 17664 7.1 Preparation at the site of use WARNING Hazard from incorrectly reprocessed products.
  • Page 20: Manual Cleaning Of The Inside

    Validated internal cleaning (removal of residual protein) can be accomplished with KaVo CLEANspray and KaVo DRYspray. ▶ Cover the medical device with the KaVo CLEANpac bag, and place it on the cor- responding servicing adapter. Press the spray button three times for 2 seconds each time.
  • Page 21: Manual Disinfection Of The The Exterior

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 7 Reprocessing steps in accordance with ISO 17664 | 7.4 Care products and systems - Servicing 7.3.1 Manual disinfection of the the exterior KaVo recommends the following products based on compatibility of the materials. The microbiological efficacy must be ensured by the disinfectant manufacturer.
  • Page 22: Packaging

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 7 Reprocessing steps in accordance with ISO 17664 | 7.5 Packaging 7.5 Packaging Note The sterilisation bag must be large enough for the instrument so that the bag is not stretched.
  • Page 23: Tools

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 8 Tools 8 Tools Available from specialised dealers ▶ Cannula 1 Mat. no. 0.573.0151 ▶ Cannula 2 Mat. no. 0.573.0181 Mat. no. 0.200.6019 O-ring for cannulas Powder container Mat.
  • Page 24: Terms And Conditions Of Warranty

    Instructions for use PROPHYflex 3 - 2018 for Sirona connection - 1.006.9920, - 1.006.9927 9 Terms and conditions of warranty 9 Terms and conditions of warranty The following warranty conditions apply to this KaVo medical device: KaVo provides the end customer with a warranty of proper function and guarantees...

Table of Contents