Operating Guide | VACON® 100 Wall-mounted Drives
Enclo-
Drive Type
I
sure
size
MR6
0007 7
7.5
0010 7
10.0
0013 7
13.5
0018 6
18.0
0018 7
0022 6
22.0
0022 7
0027 6
27.0
0027 7
0034 6
34.0
0034 7
MR7
0041 6
41.0
0041 7
0052 6
52.0
0052 7
0062 6
62.0
0062 7
MR8
0080 6
80.0
0080 7
0100 6
100.0
0100 7
0125 6
125.0
0125 7
MR9A
0144 6
144.0
0144 7
0170 6
170.0
0170 7
0208 6
208.0
0208 7
108 | Danfoss A/S © 2019.05
[A]
Fuse
Mains, motor, and brake resistor
L
(gG/g
cable Cu [mm
L) [A]
10
3x2.5+2.5
16
3x2.5+2.5
16
3x6+6
20
3x10+10
25
3x10+10
32
3x10+10
35
3x16+16
50
3x16+16 (Cu)
3x25+16 (Al)
63
3x25+16 (Cu)
3x35+16 (Al)
63
3x25+16 (Cu)
3x35+16 (Al)
80
3x35+16 (Cu)
3x50+21 (Al)
100
3x50+25 (Cu)
3x70+21 (Al)
125
3x70+35 (Cu)
3x95+29 (Al)
160
3x70+35 (Cu)
3x120+41 (Al)
200
3x95+50 (Cu)
3x150+41 (Al)
250
3x120+70 (Cu)
3x185+57 (Al)
(1)
2
]
Mains terminal cable size
2
[mm
]
2.5–50 Cu/Al
2.5–50 Cu/Al
2.5–50 Cu/Al
2.5–50 Cu/Al
2.5–50 Cu/Al
2.5–50 Cu/Al
2.5–50 Cu/Al
6–70 Cu/Al
6–70 Cu/Al
6–70 Cu/Al
Bolt size M8
Bolt size M8
Bolt size M8
Bolt size M10
Bolt size M10
Bolt size M10
AQ298036140958en-000101 / DPD01711
Specifications
Grounding
terminal ca-
ble size
2
[mm
]
2.5–35
2.5–35
2.5–35
2.5–35
2.5–35
2.5–35
2.5–35
6–70
6–70
6–70
Bolt size M8
Bolt size M8
Bolt size M8
Bolt size M8
Bolt size M8
Bolt size M8