Relay outputs OUT4 and OUT5, as well as OUT6 and OUT7: Terminals 25, 26, 27 and terminals 28,
29, 30
Contact type
Rated contact current
UL Rating
Output voltage (maximum)
Mechanical / electrical endurance
Insulation voltage U
Design of insulation
Impulse withstand voltage U
Operating frequency impulse withstand volt-
age
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Maximum degree of pollution
Overvoltage category
Measuring category
Connections
Connecting terminals
Cable cross-section (min-max)
Cable cross-section (min-max) acc. to UL 508
Tightening torque
Enclosure
Enclosure material
Version
Degree of protection
Weight
3KC ATC6300 transfer control device
Manual, 03/2018, L1V30535632002A-01
i
imp
4x1 NO contacts (OUT4 and OUT5 as well as
OUT6-7 with common control terminal)
AC1 8 A 250 V
DC1 8A 30 V
AC15 1.5 A 250 V
B300
30 V DC 1A pilot duty
250 V AC
1x10^7 / 1x10^5
250 V AC
Single between OUT4-5 and between OUT6-7
Double for the remaining groups
Single / double
4.8 kV / 7.3 kV
1.5 / 3 kV
-30 ... +70 °C
-30 ... +80 °C
< 80 % (IEC / EN 60068-2-70)
2
3
CAT III
Removable / plug-in
0.2 ... 2.5 mm
(AWG 24 ... 12)
2
0.75 ... 2.5 mm
(AWG 18 ... 12)
2
0.56 Nm (5 lbf-in)
Polyamide
Door installation
IP40 at front (can be increased to IP65 by using
cover frame), IP20 at rear
600 g
Technical specifications