Maple Systems Silver Series Installation And Operation Manual page 70

Operator interface terminal
Hide thumbs Also See for Silver Series:
Table of Contents

Advertisement

66
Beginning Window No: Indicates what window-0 number EasyBuilder will start using when numbering
windows. When the project is first created in EasyBuilder, the software automatically creates a beginning
window. EasyBuilder can be set to start numbering windows that are created, starting with the initial
window at either 10 or 1. The default and recommended setting is to start at 10.
Compiler Level: Used to set the compiler warning level. Before a project can be downloaded to the OIT,
the project has to be saved and compiled. EasyBuilder can generate two levels of compiler messages. Level
0 is the minimum level and generates only error messages. Level 1 is the highest level, and generates both
error and warning messages regarding part and PLC address size mismatch. Level 0 is the default setting.
The Part Layout setting allows you to control the level on which objects are displayed during runtime. The
Control setting causes the OIT to bring objects to the top layer when the object is updated. The Nature
setting causes the OIT to leave the objects on the layer in which they were placed during development.
Address Mode : Allows the OIT to access more than one PLC. Select extended when connecting to
multiple PLCs. Select standard if connecting to one PLC only. For more information on this feature, see
Networking Multiple Controllers Using Modbus RTU Extended V3 Protocol at the end of this chapter.
1010-1001a, Rev 02
Sil ver Se ries In stal la tion & Op er a tion Man ual