Rep re senting Data with Graph ics Ob jects
Dec. value:
Bottom limit:
JOG—
JOG delay:
JOG speed:
Set at window
open
Set value:
Set at window
close
Set value:
Inc. value:
Periodical JOG++
Upper limit:
Break time:
Dec. value:
Periodical JOG—
Bottom limit:
Break time:
Periodical bounce
Inc. value:
Upper limit:
Break time:
Low limit:
Step up
Upper limit:
Break time:
Low limit:
Step down
Upper limit:
Break time:
Set at window
maximized
Set value:
Decreases the value in a 16-bit PLC register by a step value each time it is pressed. If the
key is held down, then it will continue to decrease by the step value at a predefined rate.
Amount of the step value. Range: 1 to 32767
The lowest range allowed. Range: -32768 to 32767
The amount of delay after the key is held down before automatic decrementing occurs.
Range: 0.1 to 1.5 seconds
The rate at which the automatic decrementing occurs.
Range: 0.1 to 1.5 seconds
Automatically places a constant value into a PLC register when the window that the part is
located in is opened.
Constant used. Range: -32768 to 65535
Automatically places a constant value into a PLC register when the window that the part is
located in is closed.
Constant used. Range: -32768 to 65535
Continuously increases the value in a 16-bit PLC register by a step value at a predefined
rate as long as the window that the part is located on is open. This is very similar to a self
resetting timer.
Amount of the step value. Range: 1 to 32767
The upper range allowed. Range: -32768 to 32767
The rate at which the automatic incrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Continuously decreases the value in a 16-bit PLC register by a step value at a predefined
rate as long as the window that the part is located on is open. This is very similar to a self
resetting timer.
Amount of the step value. Range: 1 to 32767
The lowest range allowed. Range: -32768 to 32767
The rate at which the automatic decrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Automatically increases the value in a 16-bit PLC register by a step value at a predefined
rate as long as the window that the part is located on is open. When the upper limit is
reached, the value automatically decreases until it reaches 0, then repeats the process
continuously.
Amount of the step value. Range: 1 to 32767
The upper range allowed. Range: 1 to 32767
The rate at which the automatic incrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Continuously increases the value in a 16-bit PLC register by 1 from a specified low limit at
a predefined rate as long as the window that the part is located on is open. When the high
limit is reached, the process repeats starting at the low limit again.
The lowest range allowed. Range: -32768 to 65535
The upper range allowed. Range: -32768 to 65535
The rate at which the automatic incrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Continuously decreases the value in a 16-bit PLC register by 1 from a specified high limit
at a predefined rate as long as the window that the part is located on is open. When the
low limit is reached, the process repeats starting at the high limit again.
The lowest range allowed. Range: -32768 to 65535
The upper range allowed. Range: -32768 to 65535
The rate at which the automatic decrementing occurs.
Range: 0.1 to 25.5 seconds in 0.1 second increments
Automatically places a 16-bit constant value into a PLC register when the window that the
part is located in is maximized.
Constant used. Range: -32768 to 65535
181