188
5. Click the Numeric tab to display the Numeric form.
6. In the Display attribute box, select the format type you wish to use. The options are:
Format
Range
Decimal
-32768 to +32767
-999999999 to +2147483647
Hex
0000 to FFFF
00000000 to FFFFFFFF
Binary
00... to 11... (16 bits)
00... to 11... (32 bits)
Mask
*****
-999999999.9999999999 to
Single Float
9999999999.9999999999
-999999999.9999999999 to
Double Float
9999999999.9999999999
7. If Decimal format is selected, then you have the option of selecting Raw data display or Do
conversion. Use Raw data display when you wish to display the true numeric value of the
register. Select Do conversion when you wish to scale the value.
8
In the Display attribute box, select the format type you wish to use. The options are:
1010-1001a, Rev 02
Sil ver Se ries In stal la tion & Op er a tion Man ual
No. of Words
Description
1
signed 16 bit format
2
signed 32 bit format
1
hexadecimal 16 bit format
2
hexadecimal 32 bit format
1
binary 16 bit format
2
binary 32 bit format
1,2
masks the value with asterisks
2
IEEE 754 format; single precision
4
IEEE 754format; double precision