HMI5000B Series Installation Guide Introduction Thank you for purchasing a Maple Systems HMI5000B Series graphic industrial operator interface terminal. This booklet describes the steps necessary for installing the following models: HMI5040B HMI5070B HMI5070Bv3 HMI5100B The HMI5000B Series touchscreens are configured using the EasyBuilder Pro software.
HMI5000B Series Touchscreen Power Connector Mounting Clamp Kit HMI5000B Series Installation Guide Warranty A copy of the Warranty and Limitation of Liability is contained in the product box. It can also be found on the Maple Systems website. 1010-1051 Rev 03 www.maplesystems.com...
Web: www.maplesystems.com Installation of HMIs Information furnished by Maple Systems is believed to be accurate and reliable. However, no responsibility is assumed by Maple Systems for the use of this information, or for any infringements of patents or other rights of third parties which may result from its use.
Environmental Considerations The HMI is designed to operate in temperatures from 0° to 50°C (32° to 122°F), (HMI5070Bv3: 0° to 55°C). It is intended for indoor installations and may not be suitable for use in certain outdoor applications. Avoid installing the HMI in environments with severe mechanical vibration or shocks.
Power Supply Selection The power supply used to power the HMI should provide an output of +10.5~28VDC (HMI5070Bv3: 24 ± 20% VDC) measured at the HMI power connector. A DC regulated power supply dedicated to the HMI is recommended. Use a power supply with adequate current rating. A...
For a more in-depth overview of ground wiring techniques, refer to Technical Note #1027, “Ground Wiring and Electrical Noise Reduction” in the Technical Notes section of the Maple Systems website. Installation It is necessary to follow all installation procedures described in this chapter for electrical noise immunity and CE compliance.
Page 8
HMI. The power cable for the HMI should be 18AWG, 2-conductor wire with a shield drain wire and protective shield (foil/braid). Cable (P/N 6030-0009) may be purchased by the foot from Maple Systems for constructing power cables. Always run the DC ground wire directly back to the signal return of the power supply.
Cutout dimensions for each particular HMI model are available for print and download from the Support Center-Dimensional Drawings section of the Maple Systems website. The area of the panel or mounting surface where the gasket comes into contact must be flat and free of scratches, pits, and other features that prevent the gasket from sealing properly.
HMI5000B Installation Guide Configuration Wiring To configure the HMI using the EasyBuilder Pro software, use the Ethernet Configuration Cable (P/N 7431-0104). If using a switch or router between the PC and the HMI, use a straight- through or crossover cable as required by the switch or router. In order to download a project to the HMI over Ethernet, the HMI must be assigned a unique IP address that is on the same subnet as the development PC.
Page 11
D a ta + T X - T X + G N D T X D R T S C T S R X D HMI5070B / HMI5070Bv3 H M I5 07 0 B DE9P DE9S COM2 COM2 COM3 COM1...