Advertisement

Quick Links

INSTALLATION MANUAL
Del
Toggle
1
F1
F4
Alarm
Ack
4
F2
F5
Help
7
F3
F6
Del
F1
F4
F2
F5
F3
F6
808 134th Street SW, Suite 120 • Everett, WA 98204 • USA • 425/745-3229
Fax: 425/745-3429 • E-mail: maple@maple-systems.com • URL: www.maple-systems.com
1010-0105, REV 03
Page
Down
2
3
0
CLEAR
5
6
ENTER
8
9
Toggle
Page
Down
1
2
3
0
Alarm
Ack
CLEAR
4
5
6
Help
ENTER
7
8
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OIT 4160B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maple Systems OIT 4160B

  • Page 1 1010-0105, REV 03 INSTALLATION MANUAL Toggle Page Down Alarm CLEAR Help ENTER Toggle Page Down Alarm CLEAR Help ENTER 808 134th Street SW, Suite 120 • Everett, WA 98204 • USA • 425/745-3229 Fax: 425/745-3429 • E-mail: maple@maple-systems.com • URL: www.maple-systems.com...
  • Page 2 COPYRIGHT NOTICE Appendix D This manual is a publication of Maple Systems, Inc., and is provided for use by its customers only. The OIT Panel Cutout Dimensions – Front View contents of the manual are copyrighted by Maple Systems, Inc.; reproduction in whole or in part, for use other than in support of Maple Systems equipment, is prohibited without the specific written permission of Maple Systems.
  • Page 3: Read Me First

    Read Me First! 4.00 Toggle Page Down [101.2] Your new Maple Systems OIT comes from the factory without any Alarm CLEAR communications protocol or operational software installed; therefore Help The OIT will NOT operate until it has been configured using •...
  • Page 4 30 days. The equipment and its accessories were inspected and tested by Maple Systems before shipment; all of the Apparatus covered by this standard is not intended for connection to a public mains equipment should be in good working order.
  • Page 5: Table Of Contents

    OIT3160B/4160B INSTALLATION MANUAL Appendix A Table of Contents OIT Hardware Specifications 1. Safety Warnings ..........6 Mechanical 1.1.
  • Page 6: Safety Warnings

    4.1. Connect OIT to PC for Configuration To configure the OIT using Maple Systems’ configuration software, remove the WARNING All input and output (I/O) wiring must be in accordance PLC/host cable from the serial port on the OIT and connect the OIT to the computer...
  • Page 7: Control Panel Design Guidelines

    OIT3160B/4160B INSTALLATION MANUAL Route the communication cable to the PLC/host. Refer to the “OIT Cable Routing” section for more information. 2. Control Panel Design Guidelines Connect the other end of the cable to the PLC/host and tighten the cable screws. The following guidelines are intended to illustrate proper installation of the OIT to PIN# FUNCTION...
  • Page 8: Power Supply Selection

    Maple Systems offers pre-constructed OIT-to-PLC communication cables for switching relays or solenoids unless noise filter caps are connected to each relay. most PLCs. Most cables are available for same day shipment from Maple Systems. They are built and tested for high reliability and are strongly recommended. Maple 2.3.
  • Page 9: Other Steps To Improve Noise Immunity

    The power cable for the OIT should be 18AWG 2-conductor wire with a shield are properly secured. wire and protective shield foil. Maple Systems sells cable P/N 6030-0009 by the foot for user-built power cables. • Any equipment used in the enclosure that operates at high frequency or high current levels can be covered with a grounded metal shield.
  • Page 10: Oit Installation

    It is necessary to follow all installation procedures described in this chapter for electrical noise immunity and CE compliance. Your Maple Systems OIT is designed to connect easily to your PLC. External connectors provide quick connection for power and communications wiring.

Table of Contents