Starting Ezware-500 - Maple Systems Silver Series Installation And Operation Manual

Operator interface terminal
Hide thumbs Also See for Silver Series:
Table of Contents

Advertisement

18
To connect your PLC to the OIT
1. Maple Systems produces PLC communications cables, which will connect the OIT to most of
the PLCs available. The cables can be manufactured to any length you may require. A listing
of all the PLC cables Maple Systems offers can be found on our website.
2. If you have decided to make your own cable, make sure that it is wired correctly for your
particular PLC. Maple Systems provides cable wiring diagrams to guide you through the
construction of your cable. These can also be found on our website.
3. Connect the PLC communications cable from the serial port on your PLC to the appropriate
serial port on your OIT.
• If you are us ing RS-232 com mu ni ca tions, then con nect the OIT end of the ca ble to the OIT
port la beled PLC[RS-232].
• If you are using RS-485 communications, then connect the OIT end of the cable to the OIT
port labeled PLC[RS-485]. If you wish to use the Y-adapter programming cable, then
connect to the cable end that is marked PLC.
4. Apply power to the PLC. The Silver Series OIT is programmed at the factory with a sample
demo that shows some features of the OIT. The OIT should display a sample startup screen.
The OIT will now accept a new project from EZware-500.

Starting EZware-500

Before you can create a sample project, you must start the configuration software. The EZware-500 software has
three main applications:
EasyBuilder – used to create the project downloaded to the OIT.
EasyManager - used to place the OIT into different operating modes.
EasyASCIIFontMaker - used to edit the text fonts that display characters on the OIT.
To start the EZware-500 software
1. From the Windows Task Bar, click the Start button, point to Programs, and then click the
EZware-500 folder.
2. Click EasyManager to start the EasyManager application.
3. Select the appropriate COM port on your computer.
4. Select a baud rate of 38400.
5. Click Project Download/Upload.
6. Click Complete Download/Upload.
7. On the EasyManager dialog box, click EasyBuilder.
8. The Welcome to EasyBuilder dialog box appears. Select the correct OIT model.
9. Click OK to display the main screen of EasyBuilder.
1010-1001a, Rev 02
After you have successfully downloaded a project to the OIT using this baud rate, try
using 115200 to decrease the required download time.
After you have downloaded your first project to the OIT, you can switch to Partial
Download/Upload to decrease the required download time.
If the main screen of EasyBuilder is displayed after you click EasyBuilder from the
EasyManager dialog box, select the correct model of OIT by clicking New from the File
menu.
Sil ver Se ries In stal la tion & Op er a tion Man ual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents