168
9057
Event Log Database Item Size
9058-9059
Event Log Database Size
Numeric Input Object and ASCII
9060-9075
Input Object data
9076-9079
Reserved for future use
9080-9085
Project name
9086-9087
Project size
9088-9089
Project size (Kbytes)
9090-9091
Compiler Version ID
9092
Project Compiled Date: Year
9093
Project Compiled Date: Month
9094
Project Compiled Date: Day
9095-9099
Reserved for future use
9100
Indirect Window Object; window #
9101
Indirect Window Object; Offset
9102-9129
Reserved for future use.
9130
Change language
9135
Battery Voltage (BIN)
9136
CF Recipe Transfer
9137-9999
Reserved for future use
Re served Rec ipe Word (RW) Ta ble
Address
Function
Real Time Clock (RTC);
60000
Seconds
Real Time Clock (RTC);
60001
Minutes
Real Time Clock (RTC);
60002
Hour
Real Time Clock (RTC);
60003
Day Of Month
1010-1001a, Rev 02
RdOnly
Management information: The size of every item.
Management information: The size of the database, the size
RdOnly
includes management information.
(Total_Item*Item_Size+management_info_size).
These 16 registers represent the latest entries, when the OIT
RdOnly
operator enters a numeric or ASCII value into one of these
objects. Register 9075 is the latest entry.
Twelve bytes are used to store the project name. Use the ASCII
RdOnly
Data Object to display on OIT.
Four bytes are used to store the size of the current project (in
RdOnly
bytes). Use the Numeric Data Object (Decimal Display) to
display on OIT
Four bytes are used to store the size of the current project (in
RdOnly
bytes). Use the Numeric Data Object (Decimal Display) to
display on OIT.
Four bytes are used to store the compiler version of the current
RdOnly
project. Use the Numeric Data Object (Decimal Display) to
display on OIT.
This register contains the year date when the project was last
RdOnly
compiled. Use the Numeric Data Object (Decimal Display) to
display on OIT.
This register contains the month date when the project was last
RdOnly
compiled. Use the Numeric Data Object (Decimal Display) to
display on OIT.
This register contains the day of month date when the project was
RdOnly
last compiled. Use the Numeric Data Object (Decimal Display) to
display on OIT.
This register stores the window number requested using the
RdOnly
Indirect Window Object
This register can be used to store an offset that is added to
R/W
LW9100 when using the Indirect Window Object
R/W
V 2.5.0 -- This register changes the language set (Values:0-3)
V 2.6.0 - Li-Battery Measurement (If value = 1175 = 3.02V) (If
value <1070 or 2.75V, then replace the battery)
RdOnly
Create a Numeric Display for LW:9135, set "Input high=1175"
and set "engineering high = 302" Then display should show
proper voltage.
0:inactive
1:Transfer in process
RdOnly
2:Transfer complete
3:Transfer failed
Access
Description
This register is used to store the seconds count for the optional
R/W
RTC; BCD code, valid values 0-59
This register is used to store the minutes count for the optional
R/W
RTC; BCD code, valid values 0-59
This register is used to store the hour count for the optional RTC;
R/W
BCD code, valid values 0-23
This register is used to store the day of the month for the optional
R/W
RTC; BCD code, valid values 0-31