10 Inspection, Maintenance, and Troubleshooting
10.1.4 Troubleshooting of Alarm and Warning
Alarm
Alarm Name
Display
A.320
Regenerative
Overload
A.330
Main Circuit
Wiring Error
A.400
Overvoltage
10-10
Table 10.3 Alarm Display and Troubleshooting (Cont'd)
Situation at Alarm
Occurrence
Occurred when the
A SERVOPACK board fault occurred.
control power
supply was turned
ON.
Occurred when the
The power supply voltage is 270 V or more.
main circuit power
supply was turned
ON
Occurred during
The regenerative energy is excessive.
normal operation
The regenerating state continued.
(large increase of
regenerative resistor
temperature)
Occurred during
The setting of parameter Pn600 is smaller than the
normal operation
external regenerative resistor's capacity.
(small increase of
A SERVOPACK fault occurred.
regenerative resistor
temperature)
Occurred at
The regenerative energy is excessive.
servomotor
deceleration
Occurred when the
A SERVOPACK board fault occurred.
control power
supply was turned
ON.
Occurred when the
In the DC power input mode, AC power is supplied
main circuit power
through L1 and L2 or L1, L2, and L3.
supply was turned
In the AC power input mode, DC power is supplied
ON.
through B1/
Pn600 is set to 0 if the regenerative resistance is
disconnected.
Occurred when the
A SERVOPACK board fault occurred.
control power
supply was turned
ON.
Occurred when the
The AC power voltage is 290 V or more.
main circuit power
supply was turned
A SERVOPACK fault occurred.
ON.
Occurred during
Check the AC power voltage (check if there is no
normal operation.
excessive voltage change.)
The motor speed is high and load moment of inertia
is excessive, resulting in insufficient regenerative
capacity.
A SERVOPACK fault occurred.
Occurred at
The motor speed is high, and the load moment of
servomotor
inertia is excessive.
deceleration.
Cause
and
terminals.
Corrective Actions
Replace the SERVOPACK.
Correct the input voltage.
Select a proper regenerative resistance capacity, or
reconsider the load and operation conditions.
Correct the set value of parameter Pn600.
Replace the SERVOPACK.
Select a proper regenerative resistance capacity, or
reconsider the load and operation conditions.
Replace the SERVOPACK.
For AC power input, Pn001.2=0.
For DC power input, Pn001.2=1.
Set Pn600 to 0.
Replace the SERVOPACK.
The AC power voltage must be within the
specified range.
Replace the SERVOPACK.
The AC power voltage must be within the
specified range.
Check the load moment of inertia and minus load
specifications. Reconsider the load and operation
conditions.
Replace the SERVOPACK.
Reconsider the load and operation conditions.