YASKAWA SGDS Sigma III Series User Manual page 246

Servo amplifier for mechatrolink-ii communications
Table of Contents

Advertisement

Operation Key
B B
P n 0 1 6
P n 0 1 7
P n 0 1 8
P n 0 1 9
If the advanced autotuning could not be successfully completed, "Error" is displayed and blinks. To cancel the function,
INFO
press the
Key. Then restart from the first step of the procedure and display the initial settings display for the
advanced autotuning initial setting display.
Then, change the gain setting level "LEVEL," for example from "0 (Loose)" to "1 (Normal)," or increase the set value
for Pn522 (positioning completion width), and re-execute the advanced autotuning.
Display
- F U N C T I O N -
Press the
mode reappears.
Example of the screen when advanced
autotuning could not be completed
E r r o r
A D V A N C E D A T
P n 1 0 3 = 0 0 1 2 3
P n 1 0 0 = 0 0 6 3 . 0
P n 1 0 1 = 0 1 7 . 0 0
P n 1 0 2 = 0 0 6 3 . 0
Description
Key. The main menu of the utility function
8.3 Advanced Autotuning
8-17