Appendix
A.5 Acceptance tests for the safety functions
Countersignatures
Commissioning engineer
The commissioning engineer confirms that the tests and checks listed above have been
correctly executed.
...
Machine manufacturer
The machine OEM confirms the correctness of the settings documented above.
...
A.5.4
Documenting the settings for the basic functions, firmware V4.4 ... V4.7 SP6
Drive = <pDO-NAME_v>
Table A- 9
Firmware version
Name
Control Unit firmware version
SI version, safety functions integrated in the drive (processor 1)
Table A- 10
Monitoring cycle
Name
SI monitoring clock cycle (processor 1)
Table A- 11
Checksums
Name
SI module identifier, Control Unit
SI module identifier, Power Module
SI reference checksum SI parameters (processor 1)
SI reference checksum SI parameters (processor 2)
342
Date
Name
...
Date
Name
...
Company/dept.
...
Company/dept.
...
Converter with the control units CU240D-2
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
Signature
...
Signature
...
Number
Value
r18
<r18_v>
r9770
<r9770_v>
Number
Value
r9780
<r9780_v>
Number
Value
r9670
<r9670_v>
r9672
<r9672_v>
p9799
<p9799_v>
p9899
<p9899_v>