Siemens Sinamics CU240D-2 DP Operating Instructions Manual page 320

Sinamics g120d distributed inverter control unit with encoder evaluation
Hide thumbs Also See for Sinamics CU240D-2 DP:
Table of Contents

Advertisement

Technical data
10.8 Electromagnetic Compatibility
Table 10- 7
EMC Phenomenon
Conducted emissions
(disturbance voltage)
Radiated emissions
Harmonic Currents
Table 10- 8
Typical Harmonic Current (% of rated input current) at U
Units installed within the category C2 (domestic) environment require supply authority
acceptance for connection to the public low-voltage power supply network. Please contact
your local supply network provider.
Units installed within the category C3 (industrial) environment do not require connection
approval.
EMC Immunity
The SINAMICS G120D drives have been tested in accordance with the immunity
requirements of category C3 (industrial) environment.
The immunity requirements apply equally to both filtered and unfiltered units.
Table 10- 9
EMC Phenomenon
Electrostatic Discharge (ESD)
318
Conducted disturbance voltage and radiated emissions
Converter type
Remark
All converters with integrated class A filters.
Article number:
6SL3525-0PE . . - . A . .
Converter frame sizes A, B and C with integrated
class A filter.
Article number:
6SL3525-0PE17- . A . .
6SL3525-0PE21- . A . .
6SL3525-0PE23- . A . .
6SL3525-0PE24- . A . .
6SL3525-0PE25- . A . .
6SL3525-0PE27- . A . .
In a domestic environment this product may cause
radio interference in which case supplementary miti-
gation measures may be required.
Harmonic Currents
5th
7th
11th
54
39
EMC Immunity
13th
17th
11
5
Standard
Level
EN 61000-4-2
4 kV Contact discharge
8 kV Air discharge
Operating Instructions, 04/2018, FW V4.9 SP10, A5E34262100B AF
Level acc. to
IEC 61800-3
Category C2
First Environment -
Professional Use
Category C2
First Environment -
Professional Use
1 %
K
19th
23rd
5
3
Converter with the control units CU240D-2
25th
2
2
Performance
Criterion
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics cu240d-2 pn-f ppSinamics cu240d-2 pn-f foSinamics cu240d-2 dp-fSinamics cu240d-2 pnSinamics cu240d-2 pn-f

Table of Contents