Malfunctions for which emergency operation can or cannot be executed when an inverter type outdoor unit
malfunctions
Tripped Safety Device
Faulty PC Board
Tripped HPS
Tripped LPS
Solenoid Valve Malfunction
Discharge Pipe Temperature Malfunction
Air Thermistor Malfunction
Discharge Pipe Thermistor Malfunction
Suction Pipe Thermistor Malfunction
Heat Exchange Thermistor Malfunction
Oil Temperature Thermistor Malfunction
Header Thermistor Malfunction
High Pressure Sensor Malfunction
Low Pressure Sensor Malfunction
Faulty Inverter System
Faulty Inverter Cooling
Compressor Motor Ground Fault
Compressor Overload, Disconnection
Compressor Lock
Inverter
Power Supply Voltage Imbalance
Power Unit Temperature Sensor Malfunction
Reverse Phase / Negative Phase
"Power Supply Voltage Malfunction, Instantaneous Failure"
Indoor - Outdoor Unit Transmission Failure
Outdoor
2. When a constant speed type outdoor unit malfunctions
When a constant speed type outdoor unit malfunctions, you can continue to operate by setting to forced
backup operation in setting mode 2. With backup operation, you can continue to operate for up to 3 hours,
but there is no time restriction for this mode.
Malfunctions for which emergency operation can or cannot be executed when a constant speed type
outdoor unit malfunctions
Malfunction
Tripped Safety Device
Faulty PC Board
Tripped LPS
Solenoid Valve Malfunction
Discharge Pipe Temperature Malfunction
Faulty Control HPS
Faulty Control LPS
Air Thermistor Malfunction
Discharge Pipe Thermistor Malfunction
Suction Pipe Thermistor Malfunction
Heat Exchange Thermistor Malfunction
Oil Temperature Thermistor Malfunction
Header Thermistor Malfunction
Reverse Phase / Negative Phase
Outdoor
Special Service Mode PLUS Series
Malfunction
Outdoor Unit PC Board Transmission Malfunction
L Transmission Malfunction
L Transmission Malfunction
: http://splitoff.ru/tehn-doc.html
Backup and Emergency Operation
Malfunction Code
Emergency Operation
E0
Can Operate
E1
Cannot Operate
E3
Can Operate
E4
Can Operate
E9
Can Operate
F3
Can Operate
H9
Can Operate
J3
Can Operate
J5
Can Operate
J6
Can Operate
JH
Can Operate
J7
Can Operate
JA
Cannot Operate
JC
Cannot Operate
L0
Can Operate
L4
Can Operate
L5
Can Operate
L8
Can Operate
L9
Can Operate
LC
Can Operate
P1
Can Operate
P4
Can Operate
U1
Cannot Operate
U2
Can Operate
U4
Cannot Operate
U7
Cannot Operate
Malfunction Code
Emergency Operation
E0
Can Operate
E1
Cannot Operate
E4
Can Operate
E9
Can Operate
F3
Can Operate
H3
Cannot Operate
H4
Cannot Operate
H9
Can Operate
J3
Can Operate
J5
Can Operate
J6
Can Operate
JH
Can Operate
J7
Can Operate
U1
Cannot Operate
U7
Cannot Operate