Vlt ® Extended Relay Card Mcb - Danfoss VLT AQUA Drive FC 202 Design Manual

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Specifications
®
7.11.4 VLT
Extended Relay Card MCB 113
The MCB 113 extends the I/O of the adjustable frequency
drive by seven digital inputs, two analog outputs, and four
SPDT relays. The extended I/O increases flexibility and
enables compliance with the German NAMUR NE37
recommendations.
The MCB 113 is a standard C1 option and is automatically
detected after mounting.
1
2
3
4
1
2
1
2
3
4
5
6
X45/
X48/
X46/
Figure 7.11 Electrical Connections of MCB 113
To ensure galvanic isolation between the adjustable
frequency drive and the option card, connect MCB 113 to
an external 24 V on X48. When galvanic isolation is not
required, the option card can be supplied through internal
24 V from the adjustable frequency drive.
Electrical Data
Relays
Numbers
Load at 250 V AC/30 V DC
Load at 250 V AC/30 V DC with cosφ = 0.4
Overvoltage category (contact - ground)
Overvoltage category (contact - contact)
Combination of 250 V and 24 V signals
Maximum throughput delay
Isolated from ground/chassis for use on IT line power systems
Digital Inputs
Numbers
Range
Mode
Input impedance
Low trigger level
High trigger level
Maximum throughput delay
Analog outputs
Numbers
Range
Resolution
Linearity
MG20N622
Design Guide
7
8
9
10
11
12
13 14
Danfoss A/S © 09/2014 All rights reserved.
NOTICE!
To connect both 24 V signals and high-voltage signals in
the relays, ensure that there is one unused relay
between the 24 V signal and the high-voltage signal.
To set up MCB 113, use parameter groups:
5-1* Digital input
6-7* Analog output 3
6-8* Analog output 4
14-8* Options
5-4* Relays
16-6* Inputs and outputs
NOTICE!
In parameter group 5-4* Relay,
Array [2] is relay 3.
Array [3] is relay 4.
Array [4] is relay 5.
Array [5] is relay 6.
Possible with one unused relay between
7
7
4 SPDT
8 A
3.5 A
III
II
10 ms
7
0–24 V
PNP/NPN
4 kW
6.4 V
17 V
10 ms
2
0/4–20 mA
11 bit
<0.2%
189