Danfoss VLT AQUA Drive FC 202 Design Manual page 166

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Specifications
Type Designation
High/normal overload
Typical shaft output at 550 V [kW]
Typical shaft output at 550 V [hp]
Typical shaft output at 690 V [kW]
Typical shaft output at 690 V [hp]
Protection rating IP20/Chassis
Protection rating IP21/Type 1
Protection rating IP55/Type 12
Output current
Continuous (3x525–550 V) [A]
Intermittent (60 s overload) (3x525–550 V) [A]
Continuous (3x551–690 V) [A]
Intermittent (60 s overload) (3x551–690 V) [A]
Continuous kVA at 550 V [kVA]
7
7
Continuous kVA at 690 V [kVA]
Maximum input current
Continuous at 550 V [A]
Intermittent (60 s overload) at 550 V [A]
Continuous at 690 V [A]
Intermittent (60 s overload) at 690 V [A]
Additional specifications
Maximum cable cross-section for line power
and motor [mm
Maximum cable cross-section for brake and
load sharing [mm
Maximum cable cross-section
disconnect [mm
Estimated power loss
at rated maximum load [W]
5)
Efficiency
Table 7.17 B4, C2, C3 Enclosure, Line Power Supply 3x525–690 V AC IP20/IP21/IP55, Chassis/NEMA1/NEMA 12, P30K–P75K
For fuse ratings, see chapter 7.7 Fuses and Circuit Breakers.
1) High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2) The three values for the maximum cable cross-section are for single core, flexible wire and flexible wire with sleeve, respectively.
3) Applies for dimensioning of adjustable frequency drive cooling. If the switching frequency is higher than the default setting, the power losses
may increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to
www.danfoss.com/vltenergyefficiency.
4) Efficiency measured at nominal current. For energy efficiency class, see chapter 7.4 Ambient Conditions. For part load losses, see
www.danfoss.com/vltenergyefficiency.
5) Measured using 5 m (10 ft) shielded motor cables at rated load and rated frequency.
6) Enclosure sizes A2+A3 can be converted to IP21 using a conversion kit. See also chapter 3.6 Mechanical Planning.
7) Enclosure sizes B3+B4 and C3+C4 can be converted to IP21 using a conversion kit. See also chapter 3.6 Mechanical Planning.
8) Enclosure sizes for N75K, N90K are D3h for IP20/Chassis, and D5h for IP54/Type 12.
9) 2 wires are required.
10) Variant not available in IP21.
164
1)
2
] ([AWG])
2
] ([AWG])
2)
for line power
2
] ([AWG])
3)
4)
Danfoss A/S © 09/2014 All rights reserved.
®
VLT
AQUA Drive FC 202
P37K
P45K
HO
NO
HO
NO
22
30
30
37
30
40
40
50
30
37
37
45
40
50
50
60
B4
C3
C2
C2
36.0
43.0
43.0
54.0
54.0
47.3
64.5
59.4
34.0
41.0
41.0
52.0
51.0
45.1
61.5
57.2
34.3
41.0
41.0
51.4
40.6
49.0
49.0
62.1
36.0
49.0
49.0
59.0
54.0
53.9
72.0
64.9
36.0
48.0
48.0
58.0
54.0
52.8
72.0
63.8
95 (3/0)
600
740
740
900
0.98
0.98
8)
P55K
P75K/N75K
HO
NO
HO
NO
37
45
45
55
50
60
60
75
45
55
55
75
60
75
75
100
C3
D3h
C2
C2
54.0
65.0
65.0
87.0
81.0
71.5
97.5
95.7
52.0
62.0
62.0
83.0
78.0
68.2
93.0
91.3
51.4
61.9
61.9
82.9
62.1
74.1
74.1
99.2
59.0
71.0
71.0
87.0
87.0
78.1
105.0
95.7
58.0
70.0
70.0
86.0
87.0
77.0
105
94.6
150 (300 MCM)
95 (3/0)
185, 150, 120
(350 MCM, 300
MCM, 4/0)
900
1100
1100
1500
0.98
0.98
8)
P90K/N90K
HO
NO
55
75
75
100
75
90
199
125
D3h
C2
87.0
105
130.5
115.5
83.0
100
124.5
110
82.9
100
99.2
119.5
87.0
99.0
129
108.9
-
-
-
-
-
1500
1800
0.98
MG20N622