System Integration

3.5.3 EMC-compliant Electrical Connection

3
3
1
9
1
PLC
2
Adjustable frequency drive
3
Output contactor
4
Cable clamp
5
Cable insulation (stripped)
6
Cable connector
Figure 3.22 EMC-compliant Electrical Connection
66
VLT
2
10
L1
L2
L3
PE
Danfoss A/S © 09/2014 All rights reserved.
®
AQUA Drive FC 202
11
8
6
7
Motor, 3--phase and PE (shielded)
8
Line power, 3--phase and reinforced PE (non-shielded)
9
Control wiring (shielded)
10
Potential equalization min. 16 mm
Clearance between control cable, motor cable and line cable:
11
Minimum 200 mm (7.9 in)
3
4
5
u
v
w
PE
7
2
2
(0.025 in
/AWG 6)
MG20N622