i.5 Start-Up Programming and Operation
Setting
13
Reverse Jog
14
Fault reset
15
Fast Stop (N.O.)
17
Fast Stop (N.C.)
18
Timer function input
19
PID disable
1A
Accel/decel time selection 2
1B
Program lockout
1E
Reference sample hold
20 to 2F Ext. pump fault
30
PID integral reset
31
PID integral hold
Multi-Step Speed
32
Reference 4
34
PID soft starter cancel
35
PID input level selection
Forward run command
40
(2-Wire sequence)
Reverse run command
41
(2-Wire sequence)
Run command
42
(2-Wire sequence 2)
FWD/REV command
43
(2-Wire sequence 2)
47
Node setup
51
Sequence Timer Disable
52
Sequence Timer Cancel
60
DC Injection Braking command
External Speed Search
61
command 1
External Speed Search
62
command 2
63
Field weakening
65
KEB Ride-Thru 1 (N.C.)
66
KEB Ride-Thru 1 (N.O.)
<1> Available in drive software versions PRG: 8552 and later.
Not available in drive models 4A0930 and 4A1200.
n
H2-01 to H2-03: Terminal M1-M2, M3-M4, and MD-ME-MF Function Selection
The drive has three multi-function output terminals.
H2-02, and H2-03.
No.
H2-01
H2-02
H2-03
Terminal MD-ME-MF Function Selection (relay)
<1> Default is F: Through Mode in drive software versions PRG: 8551 and earlier.
Setting
0
During run
1
Zero speed
2
Speed agree 1
3
User-set speed agree 1
60
Function
Parameter Name
Terminal M1-M2 Function Selection (relay)
Terminal M3-M4 Function Selection (relay)
Table i.23 Multi-Function Digital Output Terminal Settings
Function
Page
Setting
67
Communications test mode
68
High Slip Braking (HSB)
6A
Drive enable
73
Low City Press
75
Up 2 command
76
Down 2 command
7A
KEB Ride-Thru 2 (N.C.)
7B
KEB Ride-Thru 2 (N.O.)
80
HAND Mode
81
HAND Mode 2
<1>
PI Switch to Aux
82
83
Alternate Multi-Setpoint (Q1-02)
84
Alternate Multi-Setpoint (Q1-03)
85
Alternate Multi-Setpoint (Q1-04)
88
Volute-Thermostat Normally Open
89
Volute-Thermostat Normally Closed
8C
Disable Pre-Charge
8D
Multi Setpoint 1
8E
Multi Setpoint 2
8F
Low Water Level
90
High Water Level
92
Reset Accum
95
Remove Drive Disable
A8
Secondary PI Disable (N.O.)
A9
Secondary PI Disable (N.C.)
AA
Secondary PI Inverse Operation
AB
Secondary PI Integral Reset
AC
Secondary PI Integral Hold
AD
Select Secondary PI Parameters
AF
Emergency Override Forward Run
B0
Emergency Override Reverse Run
Table i.23
lists the functions available for these terminals using H2-01,
Page
Setting
4
Frequency detection 1
5
Frequency detection 2
6
Drive ready
7
DC bus undervoltage
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide
Function
Setting Range
0 to 192
37: During Frequency Output
0 to 192
42: Pressure Reached
0 to 192
Function
Page
Default
<1>
E: Fault
Page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-pw*a series

Table of Contents