i.4 Electrical Installation
n
Three-Phase 600 V Class
Drive Model
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
5A0003
⊖, ⊕1, ⊕2
5A0004
5A0006
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1, ⊕2
5A0009
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1, ⊕2
5A0011
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1, ⊕2
5A0017
B1, B2
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
⊖, ⊕1, ⊕2
5A0022
B1, B2
32
Table i.6 Wire Gauge and Torque Specifications (Three-Phase 600 V Class)
Recomm. Gauge
Terminal
mm
Wire Range
2
(AWG, kcmil)
mm
2
(AWG, kcmil)
2.5
2.5 to 6.0
(14)
(14 to 10)
2.5
2.5 to 6.0
(14)
(14 to 10)
2.5 to 6.0
–
(14 to 10)
2.5 to 6.0
–
(14 to 10)
6.0
2.5 to 6.0
(10)
(14 to 10)
2.5
2.5 to 6.0
(14)
(14 to 10)
2.5
2.5 to 6.0
(14)
(14 to 10)
2.5 to 6.0
–
(14 to 10)
2.5 to 6.0
–
(14 to 10)
6.0
4.0 to 6.0
(10)
(12 to 10)
6.0
2.5 to 16
(10)
(14 to 6)
2.5
2.5 to 16
(14)
(14 to 6)
2.5 to 16
–
(14 to 6)
2.5 to 6.0
–
(14 to 10)
10
4.0 to 6.0
(8)
(12 to 8)
6.0
6.0 to 16
(10)
(10 to 6)
6.0
6.0 to 16
(10)
(10 to 6)
6.0 to 16
–
(10 to 6)
6.0 to 10
–
(10 to 8)
10
6.0 to 10
(8)
(12 to 8)
10
6.0 to 16
(8)
(10 to 6)
6.0
6.0 to 16
(10)
(10 to 6)
6.0 to 16
–
(10 to 6)
6.0 to 10
–
(10 to 8)
10
6.0 to 10
(8)
(10 to 6)
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide
Screw
Tightening Torque
Size
N·m (lb.in.)
1.2 to 1.5
M4
(10.6 to 13.3)
1.2 to 1.5
M4
(10.6 to 13.3)
2.1 to 2.3
M4
(18.6 to 20.4)
2.0 to 2.5
M5
(17.7 to 22.1)
3.6 to 4.0
(31.8 to 35.4)
M5
2.7 to 3.0
(23.9 to 26.6)
5.4 to 6.0
M6
(47.8 to 53.1)
3.6 to 4.0
(31.8 to 35.4)
M5
2.7 to 3.0
(23.9 to 26.6)
5.4 to 6.0
M6
(47.8 to 53.1)