YASKAWA iQpump1000 Installation & Start?Up Manual page 16

Intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

i.3 Mechanical Installation
Remove the top protective covers of all drives as shown in
drives side-by-side. Refer to the drive Quick Start Guide for instructions on removing and reattaching the top protective cover.
u
Instructions on Installation Using the Eye Bolts
Eye bolts are used to install the drive or to temporarily lift the drive when replacing it. Using the eye bolts, the drive can be
installed in an enclosure panel or on a wall. Do not leave the drive suspended by the wires in a horizontal or vertical position
for long periods of time. Do not transport the drive over long distances. Read the following precautions and instructions before
installing the drive.
WARNING! Crush Hazard. Observe the following instructions and precautions. Failure to comply could result in serious injury or death from
falling equipment.
Only use vertical suspension to temporarily lift the drive during installation to an enclosure panel. Do not use vertical suspension to transport
the drive.
Use screws to securely affix the drive front cover, terminal blocks, and other drive components prior to vertical suspension.
Do not subject the drive to vibration or impact greater than 1.96 m/s
Do not leave the drive unattended while it is suspended by the wires.
Do not attempt to flip the drive over while it is suspended by the wires.
n
Horizontal Suspension of Drive Models 2A0360, 2A0415, and 4A0250 to 4A0675
To make a wire hanger or frame for use when lifting the drive with a crane, lay the drive in a horizontal position and pass a
wire through the holes of the four eye bolts.
NOTICE: Damage to Equipment. When lifting the drive, confirm that the spring washer is fully closed. Failure to comply may deform or
damage the drive when lifted.
A – No space between drive and
Figure 2.7
B – Spring washer fully closed
n
Vertical Suspension of Drive Models 2A0360, 2A0415, and 4A0250 to 4A1200
Models 2A0360, 2A0415, and 4A0250 to 4A0675
When vertical suspension of the drive is required in an enclosure panel, change the orientation of the eye bolts for these models
by turning the eye bolts counterclockwise 90 degrees.
16
Figure i.7 IP20/NEMA 1, UL Type 1 Side-by-Side Mounting in Enclosure
B
A
washer
Figure i.8 Spring Washer
Figure i.7
when mounting IP20/NEMA 1, UL Type 1 enclosure
2
(0.2 G) while it is suspended by the wires.
D
C
C – Space between drive and washer
D – Spring washer open
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cimr-pw*a series

Table of Contents