YASKAWA iQpump1000 Installation & Start?Up Manual page 109

Intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

<5> Class L fuse is also approved for this rating.
Wiring Fuses for Models 4A0930 and 4A1200
NOTICE: If a fuse is blown or an Ground Fault Circuit Interrupter (GFCI) is tripped, check the wiring and the selection of peripheral devices
to identify the cause. Contact Yaskawa before restarting the drive or the peripheral devices if the cause cannot be identified.
Install a fuse on the input side to protect drive wiring and prevent other secondary damage. Wire the fuse so that leakage
current in the upper controller power supply will trigger the fuse and shut off the power supply.
Select the appropriate fuse from
Voltage
Model
Class
Input Voltage
Three-
4A0930
Phase
400 V
Class
4A1200
n
Low Voltage Wiring for Control Circuit Terminals
Wire low voltage wires with NEC Class 1 circuit conductors. Refer to national state or local codes for wiring. The external
power supply shall be a UL listed Class 2 power supply source or equivalent only.
Input / Output
Digital inputs
Analog inputs / outputs
n
Drive Short Circuit Rating
The drive is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical Amperes, 240 Vac
maximum (200 V Class), 480 Vac maximum (400 V Class), and 600 Vac maximum (600 V Class) when protected by Bussmann
Type FWH or FWP fuses as specified in
u
CSA Standards Compliance
n
CSA for Industrial Control Equipment
The drive is CSA-certified as Industrial Control Equipment Class 3211.
Specifically, the drive is certified to: CAN/CSA C22.2 No. 04-04 and CAN/CSA C22.2 No.14-05.
u
Drive Motor Overload Protection
Set parameter E2-01 (motor rated current) to the appropriate value to enable motor overload protection. The internal motor
overload protection is UL Listed and in accordance with the NEC and CEC.
n
E2-01: Motor Rated Current
Setting Range: Model-dependent
Default Setting: Model-dependent
YASKAWA TOEP YAIP1W 02E YASKAWA AC Drive - iQpump1000 Installation & Start-up Guide
Table
i.3.
Table i.28 Input Fuses for Models 4A0930 and 4A1200
Selection
Current
480 V
1500 A
480 V
1500 A
Table i.29 Control Circuit Terminal Power Supply
Terminal Signal
S1 to S8, SC
+V, A1, A2, A3, AC, AM, FM
Factory Recommended Branch Circuit Protection
Pre-arc
Model
I
2
t (A
2
s)
CS5F-1200
140000 to
3100000
FWH-1200A
CS5F-1500
320000 to
3100000
FWH-1600A
Use the internal LVLC power supply of the drive. Use class
2 for external power supply.
Use the internal LVLC power supply of the drive. Use class
2 for external power supply.
Figure i.38 CSA Mark
i.9 Standards Compliance
Input Fuse (Example)
Manufacturer
Rating
Fuji Electric
AC500 V, 1200 A
Bussman
AC500 V, 1200 A
Fuji Electric
AC500 V, 1500 A
Bussman
AC500 V, 1600 A
Power Supply Specifications
on page 98.
Pre-arc
I
2
t (A
2
s)
276000
351000
109

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: