i.9 Standards Compliance
Three-Phase 200 V / 400 V Class
A – Make sure the ground wire is
B – Grounding surface (remove any
C – Metal plate
D – Enclosure panel
E – Drive
F – Motor cable (braided shield cable,
Figure i.36 EMC Filter and Drive Installation for CE Compliance (Three-Phase 200 V / 400 V Class)
102
K
J
grounded
paint or sealant)
max. 10 m)
A
B
I
H
G
G – Motor
H – Cable shield ground
I – Cable clamp
J – Ground plate (scrape off any
visible paint)
K – EMC noise filter