A5 Event Recorder; Event Recorder - GE 489 Instruction Manual

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

5.6 A5 EVENT RECORDER

5.6 A5 EVENT RECORDER
T
[ENTER] for E65535
No Event
5
5-22
ð
TIME OF E65535:
ENTER
00:00:00.0
ESCAPE
DATE OF E65535:
ESCAPE
Jan. 01, 1992
MESSAGE
ACTIVE SETPOINT
ESCAPE
GROUP E65535: 1
MESSAGE
TACHOMETER
ESCAPE
E65535: 3600 RPM
MESSAGE
A:
0
B:
ESCAPE
C:
0
A
E65535
MESSAGE
a:
0
b:
ESCAPE
c:
0
A
MESSAGE
NEG. SEQ. CURRENT
ESCAPE
E65535: 0% FLA
MESSAGE
GROUND CURRENT
ESCAPE
E65535: 0.00 A
MESSAGE
Vab:
0
Vbc:
ESCAPE
Vca:
0
V
E65535
MESSAGE
FREQUENCY
ESCAPE
E65535: 0.00 Hz
MESSAGE
NEUTRAL VOLT (FUND)
ESCAPE
E65535:
0.0 V
MESSAGE
NEUTRAL VOLT (3rd)
ESCAPE
E65535:
0.0 V
MESSAGE
Vab/Iab E65535:
ESCAPE
0.0 Ωsec.
MESSAGE
REAL POWER (MW)
ESCAPE
E65535:
0.000
MESSAGE
REACTIVE POWER Mvar
ESCAPE
E65535:
0.000
MESSAGE
APPARENT POWER MVA
ESCAPE
E65535:
0.000
MESSAGE
HOTTEST STATOR
ESCAPE
RTD#1: 0°C
E65535
MESSAGE
HOTTEST BEARING
ESCAPE
RTD#7: 0°C
E65535
MESSAGE
HOTTEST OTHER
ESCAPE
RTD#11: 0°C
E65535
MESSAGE
AMBIENT
ESCAPE
RTD#12 0°C
E65535
MESSAGE
ANALOG INPUT 1
ESCAPE
E65535: 0.0 Units
MESSAGE
489 Generator Management Relay
Range: hour:minutes:seconds
Seen only if there has been an event.
Range: month day, year
Seen only if there has been an event.
Range: 1, 2
Range: 0 to 3600 RPM. Seen only if a Digital Input is
programmed as Tachometer
Range: 0 to 999999 A. Represents current measured
0
from the output CTs. Seen only if there has been
an event.
Range: 0 to 999999 A. Represents differential current.
0
Seen only if the differential element is enabled.
E6
Range: 0 to 2000% FLA
Seen only if there has been an event.
Range: 0.00 to 20000.0 A. Not seen if the GROUND CT
is programmed as None.
Range: 0 to 50000 V. Not seen if VT CONNECTION is
0
programmed as None.
Range: 0.00 to 90.00 Hz. Not seen if VT CONNECTION
is programmed as None.
Range: 0.0 to 25000.0 V.
Seen only if there is a neutral voltage transformer.
Range: 0.0 to 25000.0 V
Seen only if there is a neutral voltage transformer.
Range: 0.0 to 6553.5 Ωsec., 0 to 359°. Seen only if the
Loss of Excitation element is Enabled.
Range: 0.000 to ±2000.000 MW. Not seen if VT
CONNECTION is programmed as None
Range: 0.000 to ±2000.000 Mvar. Not seen if VT
CONNECTION is programmed as None
Range:0.000 to 2000.000 MVA. Not seen if VT
CONNECTION is programmed as None
Range: –50 to +250°C. Seen only if 1 or more RTDs are
programmed as Stator.
Range: –50 to +250°C. Seen only if 1 or more RTDs are
programmed as Bearing.
Range: –50 to +250°C. Seen only if 1 or more RTDs are
programmed as Other.
Range: –50 to +250°C. Seen only if 1 or more RTDs are
programmed as Ambient.
Range: –50000 to 50000
Seen only if the Analog Input is in use.
5 ACTUAL VALUES

5.6.1 EVENT RECORDER

GE Power Management