6.3 MEMORY MAP
Table 6–1: 489 MEMORY MAP (Sheet 18 of 29)
ADDR NAME
20A9
OVERFREQUENCY TRIP LEVEL1
20AA
OVERFREQUENCY TRIP DELAY1
20AB
OVERFREQUENCY TRIP LEVEL2
20AC OVERFREQUENCY TRIP DELAY2
VOLTAGE ELEMENTS / NEUTRAL O/V (FUND)
20C0
NEUTRAL OVERVOLTAGE ALARM
20C1
ASSIGN ALARM RELAYS (2-5)
20C2
NEUTRAL O/V ALARM LEVEL
20C3
NEUTRAL OVERVOLTAGE ALARM DELAY
20C4
NEUTRAL OVERVOLTAGE ALARM EVENTS
20C5
NEUTRAL OVERVOLTAGE TRIP
20C6
ASSIGN TRIP RELAYS (1-4)
20C7
NEUTRAL O/V TRIP LEVEL
20C8
NEUTRAL OVERVOLTAGE TRIP DELAY
20C9
SUPERVISE WITH DIGITAL INPUT
20CA NEUTRAL O/V CURVE RESET RATE
20CB NEUTRAL O/V TRIP ELEMENT
VOLTAGE ELEMENTS / NEUTRAL U/V (3rd)
20E0
LOW POWER BLOCKING LEVEL
20E2
LOW VOLTAGE BLOCKING LEVEL
20E3
NEUTRAL UNDERVOLTAGE ALARM
20E4
ASSIGN ALARM RELAYS (2-5)
20E5
NEUTRAL U/V ALARM LEVEL
20E6
NEUTRAL UNDERVOLTAGE ALARM DELAY
20E7
NEUTRAL UNDERVOLTAGE ALARM EVENTS
20E8
NEUTRAL UNDERVOLTAGE TRIP
20E9
ASSIGN TRIP RELAYS (1-4)
20EA
NEUTRAL U/V TRIP LEVEL
6
20EB
NEUTRAL UNDERVOLTAGE TRIP DELAY
VOLTAGE ELEMENTS / LOSS OF EXCITATION
2100
ENABLE VOLTAGE SUPERVISION
2101
VOLTAGE LEVEL
2102
CIRCLE 1 TRIP
2103
ASSIGN CIRCLE 1 TRIP RELAYS (1-4)
2104
CIRCLE 1 DIAMETER
2105
CIRCLE 1 OFFSET
2106
CIRCLE 1 TRIP DELAY
2107
CIRCLE 2 TRIP
2108
ASSIGN CIRCLE 2 TRIP RELAYS (1-4)
2109
CIRCLE 2 DIAMETER
210A
CIRCLE 2 OFFSET
210B
CIRCLE 2 TRIP DELAY
VOLTAGE ELEMENTS / DISTANCE ELEMENT
2130
STEP UP TRANSFORMER SETUP
2131
FUSE FAILURE SUPERVISION
2132
ZONE 1 TRIP
2133
ASSIGN ZONE 1 TRIP RELAYS (1-4)
2134
ZONE 1 REACH
2135
ZONE 1 ANGLE
2136
ZONE 1 TRIP DELAY
2137
ZONE 2 TRIP
2138
ASSIGN ZONE 2 TRIP RELAYS (1-4)
2139
ZONE 2 REACH
1, 2, 3
See Table footnotes on page 6–39
6-28
RANGE
2501 to 7000
1 to 50000
2501 to 7000
1 to 50000
0 to 2
1 to 4
20 to 1000
1 to 1200
0 to 1
0 to 2
0 to 3
20 to 1000
1 to 1200
0 to 1
0 to 9999
0 to 1
2 to 99
50 to 100
0 to 2
1 to 4
5 to 200
5 to 120
0 to 1
0 to 2
0 to 3
5 to 200
5 to 120
0 to 1
70 to 100
0 to 2
0 to 3
25 to 3000
10 to 3000
1 to 100
0 to 2
0 to 3
25 to 3000
10 to 3000
1 to 100
0 to 1
0 to 1
0 to 2
0 to 3
1 to 5000
50 to 85
0 to 1500
0 to 2
0 to 3
1 to 5000
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
Hz
F3
1
s
F2
1
Hz
F3
1
s
F2
1
F115
1
F50
1
V
F2
1
s
F2
1
F105
1
F115
1
F50
1
V
F2
1
s
F2
1
F103
1
s
F2
1
F208
× Rated MW
1
F14
× Rated
1
F3
1
F115
1
F50
1
V
F2
1
s
F1
1
F105
1
F115
1
F50
1
V
F2
1
s
F1
1
F103
× rated
1
F3
1
F115
1
F50
Ω s
1
F2
Ω s
1
F2
1
s
F2
1
F115
1
F50
Ω s
1
F2
Ω s
1
F2
1
s
F2
1
F219
1
F105
1
F115
1
F50
Ω s
1
F2
1
°
F1
1
s
F2
1
F115
1
F50
Ω s
1
F2
GE Power Management
DEFAULT
6050
600
6200
300
0
16
30
10
0
0
1
50
10
0
0
1
5
75
0
16
5
30
0
0
1
10
30
0
70
0
1
250
25
50
0
1
350
25
50
0
0
0
1
100
75
4
0
1
100

Advertisement