GE 489 Instruction Manual page 180

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6.3 MEMORY MAP
Table 6–1: 489 MEMORY MAP (Sheet 26 of 29)
ADDR NAME
2B46
ANALOG INPUT 1 MAX
2B48
ANALOG INPUT 2 MIN
2B4A
ANALOG INPUT 2 MAX
2B4C ANALOG INPUT 3 MIN
2B4E
ANALOG INPUT 3 MAX
2B50
ANALOG INPUT 4 MIN
2B52
ANALOG INPUT 4 MAX
2B54
TACHOMETER MIN
2B55
TACHOMETER MAX
2B56
THERM. CAPACITY USED MIN
2B57
THERM. CAPACITY USED MAX
2B58
NEUTRAL VOLT THIRD MIN
2B5A
NEUTRAL VOLT THIRD MAX
2B5C CURRENT DEMAND MIN
2B5D CURRENT DEMAND MAX
2B5E
Mar DEMAND MIN
2B5F
Mar DEMAND MAX
2B60
MW DEMAND MIN
2B61
MW DEMAND MAX
2B62
MVA DEMAND MIN
2B63
MVA DEMAND MAX
ANALOG I/O / ANALOG INPUT 1
2C00
ANALOG INPUT1
2C05
ANALOG INPUT1 UNITS
2C08
ANALOG INPUT1 MINIMUM
2C0A ANALOG INPUT1 MAXIMUM
2C0C BLOCK ANALOG INPUT1 FROM ONLINE
2C0D ANALOG INPUT1 ALARM
6
2C0E ASSIGN ALARM RELAYS (2-5)
2C0F
ANALOG INPUT1 ALARM LEVEL
2C11
ANALOG INPUT1 ALARM PICKUP
2C12
ANALOG INPUT1 ALARM DELAY
2C13
ANALOG INPUT1 ALARM EVENTS
2C14
ANALOG INPUT1 TRIP
2C15
ASSIGN TRIP RELAYS (1-4)
2C16
ANALOG INPUT1 TRIP LEVEL
2C18
ANALOG INPUT1 TRIP PICKUP
2C19
ANALOG INPUT1 TRIP DELAY
2C1A ANALOG INPUT1 NAME
ANALOG I/O / ANALOG INPUT 2
2C40
ANALOG INPUT2
2C45
ANALOG INPUT2 UNITS
2C48
ANALOG INPUT2 MINIMUM
2C4A ANALOG INPUT2 MAXIMUM
2C4C BLOCK ANALOG INPUT2 FROM ONLINE
2C4D ANALOG INPUT2 ALARM
2C4E ASSIGN ALARM RELAYS (2-5)
2C4F
ANALOG INPUT2 ALARM LEVEL
2C51
ANALOG INPUT2 ALARM PICKUP
2C52
ANALOG INPUT2 ALARM DELAY
2C53
ANALOG INPUT2 ALARM EVENTS
2C54
ANALOG INPUT2 TRIP
2C55
ASSIGN TRIP RELAYS (1-4)
1, 2, 3
See Table footnotes on page 6–39
6-36
RANGE
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
0 to 7200
0 to 7200
0 to 100
0 to 100
0 to 250000
0 to 250000
0 to 2000
0 to 2000
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 3
0 to 6
–50000 to 50000
–50000 to 50000
0 to 5000
0 to 2
1 to 4
–50000 to 50000
0 to 1
1 to 3000
0 to 1
0 to 2
0 to 3
–50000 to 50000
0 to 1
1 to 3000
0 to 12
0 to 3
0 to 6
–50000 to 50000
–50000 to 50000
0 to 5000
0 to 2
1 to 4
–50000 to 50000
0 to 1
1 to 3000
0 to 1
0 to 2
0 to 3
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
RPM
F1
1
RPM
F1
1
%
F1
1
%
F1
1
Volts
F10
1
Volts
F10
× FLA
1
F3
× FLA
1
F3
× Rated
1
F3
× Rated
1
F3
× Rated
1
F3
× Rated
1
F3
× Rated
1
F3
× Rated
1
F3
1
F129
1
F22
1
Units
F12
1
Units
F12
1
s
F1
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F105
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F22
1
F129
1
F22
1
Units
F12
1
Units
F12
1
s
F1
1
F115
1
F50
1
Units
F12
1
F130
1
s
F2
1
F105
1
F115
1
F50
GE Power Management
DEFAULT
50000
0
50000
0
50000
0
50000
3500
3700
0
100
0
450
0
125
0
125
0
125
0
125
0
_
0
100
0
0
16
10
0
1
0
0
1
20
0
1
_
0
_
0
100
0
0
16
10
0
1
0
0
1