6.3 MEMORY MAP
Table 6–1: 489 MEMORY MAP (Sheet 4 of 29)
ADDR NAME
0320
RTD #12 PICKUP
0321
OPEN SENSOR PICKUP
0322
SHORT/LOW TEMP PICKUP
0323
THERMAL MODEL PICKUP
0324
TRIP COUNTER PICKUP
0325
BREAKER FAILURE PICKUP
0326
TRIP COIL MONITOR PICKUP
0327
VT FUSE FAILURE PICKUP
0328
CURRENT DEMAND PICKUP
0329
MW DEMAND PICKUP
032A
Mvar DEMAND PICKUP
032B
MVA DEMAND PICKUP
032C
ANALOG INPUT 1 PICKUP
032D
ANALOG INPUT 2 PICKUP
032E
ANALOG INPUT 3 PICKUP
032F
ANALOG INPUT 4 PICKUP
0330
NOT PROGRAMMED PICKUP
0331
SIMULATION MODE PICKUP
0332
OUTPUT RELAYS FORCED PICKUP
0333
ANALOG OUTPUT FORCED PICKUP
0334
TEST SWITCH SHORTED PICKUP
0335
GROUND DIRECTIONAL PICKUP
0336
IRIG-B ALARM PICKUP
0337
GENERATOR RUNNING HOUR PICKUP
STATUS / DIGITAL INPUTS
0380
ACCESS SWITCH STATE
0381
BREAKER STATUS SWITCH STATE
0382
ASSIGNABLE DIGITAL INPUT1 STATE
6
0383
ASSIGNABLE DIGITAL INPUT2 STATE
0384
ASSIGNABLE DIGITAL INPUT3 STATE
0385
ASSIGNABLE DIGITAL INPUT4 STATE
0386
ASSIGNABLE DIGITAL INPUT5 STATE
0387
ASSIGNABLE DIGITAL INPUT6 STATE
0388
ASSIGNABLE DIGITAL INPUT7 STATE
0389
TRIP COIL SUPERVISION
STATUS / REAL TIME CLOCK
03FC
DATE (READ-ONLY)
03FE
TIME (READ-ONLY)
METERING DATA / CURRENT METERING
0400
PHASE A OUTPUT CURRENT
0402
PHASE B OUTPUT CURRENT
0404
PHASE C OUTPUT CURRENT
0406
PHASE A NEUTRAL-SIDE CURRENT
0408
PHASE B NEUTRAL-SIDE CURRENT
040A
PHASE C NEUTRAL-SIDE CURRENT
040C
PHASE A DIFFERENTIAL CURRENT
040E
PHASE B DIFFERENTIAL CURRENT
0410
PHASE C DIFFERENTIAL CURRENT
0412
AVERAGE PHASE CURRENT
0414
GENERATOR LOAD
0415
NEGATIVE SEQUENCE CURRENT
0416
GROUND CURRENT
0420
PHASE A CURRENT ANGLE
1, 2, 3
See Table footnotes on page 6–39
6-14
RANGE
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 4
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
N/A
N/A
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 999999
0 to 2000
0 to 2000
0 to 10000
0 to 359
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F123
1
F207
1
F207
1
F207
1
F207
1
F207
1
F207
1
F207
1
F207
1
F207
1
F132
N/A
N/A
F18
N/A
N/A
F19
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
Amps
F12
1
% FLA
F1
1
% FLA
F1
1
Amps
F14
1
°
F1
GE Power Management
DEFAULT
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
N/A
N/A
0
0
0
0
0
0
0
0
0
0
0
0
0
0