6.3 MEMORY MAP
Table 6–1: 489 MEMORY MAP (Sheet 6 of 29)
ADDR NAME
04AC RTD #11 TEMPERATURE
04AD RTD #12 TEMPERATURE
04C0
HOTTEST STATOR RTD TEMPERATURE
04C1
RTD #1 TEMPERATURE
04C2
RTD #2 TEMPERATURE
04C3
RTD #3 TEMPERATURE
04C4
RTD #4 TEMPERATURE
04C5
RTD #5 TEMPERATURE
04C6
RTD #6 TEMPERATURE
04C7
RTD #7 TEMPERATURE
04C8
RTD #8 TEMPERATURE
04C9
RTD #9 TEMPERATURE
04CA RTD #10 TEMPERATURE
04CB RTD #11 TEMPERATURE
04CC RTD #12 TEMPERATURE
METERING DATA / DEMAND METERING
04E0
CURRENT DEMAND
04E2
MW DEMAND
04E4
Mvar DEMAND
04E6
MVA DEMAND
04E8
PEAK CURRENT DEMAND
04EA
PEAK MW DEMAND
04EC PEAK Mvar DEMAND
04EE
PEAK MVA DEMAND
METERING DATA / ANALOG INPUTS
0500
ANALOG INPUT 1
0502
ANALOG INPUT 2
0504
ANALOG INPUT 3
6
0506
ANALOG INPUT 4
METERING DATA / SPEED
0520
TACHOMETER
LEARNED DATA / PARAMETER AVERAGES
0600
AVERAGE GENERATOR LOAD
0601
AVERAGE NEG. SEQ. CURRENT
0602
AVERAGE PHASE-PHASE VOLTAGE
0603
RESERVED
0604
RESERVED
LEARNED DATA / RTD MAXIMUMS
0620
RTD #1 MAX. TEMP.
0621
RTD #2 MAX. TEMP.
0622
RTD #3 MAX. TEMP.
0623
RTD #4 MAX. TEMP.
0624
RTD #5 MAX. TEMP.
0625
RTD #6 MAX. TEMP.
0626
RTD #7 MAX. TEMP.
0627
RTD #8 MAX. TEMP.
0628
RTD #9 MAX. TEMP.
0629
RTD #10 MAX. TEMP.
062A
RTD #11 MAX. TEMP.
062B
RTD #12 MAX. TEMP.
0640
RTD #1 MAX. TEMP.
0641
RTD #2 MAX. TEMP.
0642
RTD #3 MAX. TEMP.
1, 2, 3
See Table footnotes on page 6–39
6-16
RANGE
–52 to 251
–52 to 251
–52 to 250
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
0 to 1000000
0 to 2000000
0 to 2000000
0 to 2000000
0 to 1000000
0 to 2000000
0 to 2000000
0 to 2000000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
0 to 7200
0 to 2000
0 to 2000
0 to 50000
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
489 Generator Management Relay
6 COMMUNICATIONS
STEP
UNITS
FORMAT
1
°C
F4
1
°C
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
Amps
F12
1
MW
F13
1
Mvar
F13
1
MVA
F13
1
Amps
F12
1
MW
F13
1
Mvar
F13
1
MVA
F13
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
RPM
F1
1
%FLA
F1
1
%FLA
F1
1
V
F1
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°C
F4
1
°F
F4
1
°F
F4
1
°F
F4
GE Power Management
DEFAULT
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52
–52

Advertisement