6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (Sheet 7 of 29)
ADDR NAME
0643
RTD #4 MAX. TEMP.
0644
RTD #5 MAX. TEMP.
0645
RTD #6 MAX. TEMP.
0646
RTD #7 MAX. TEMP.
0647
RTD #8 MAX. TEMP.
0648
RTD #9 MAX. TEMP.
0649
RTD #10 MAX. TEMP.
064A
RTD #11 MAX. TEMP.
064B
RTD #12 MAX. TEMP.
LEARNED DATA / ANALOG IN MIN/MAX
0700
ANALOG INPUT 1 MINIMUM
0702
ANALOG INPUT 1 MAXIMUM
0704
ANALOG INPUT 2 MINIMUM
0706
ANALOG INPUT 2 MAXIMUM
0708
ANALOG INPUT 3 MINIMUM
070A
ANALOG INPUT 3 MAXIMUM
070C
ANALOG INPUT 4 MINIMUM
070E
ANALOG INPUT 4 MAXIMUM
MAINTENANCE / TRIP COUNTERS
077F
TRIP COUNTERS LAST CLEARED (DATE)
0781
TOTAL NUMBER OF TRIPS
0782
DIGITAL INPUT TRIPS
0783
SEQUENTIAL TRIPS
0784
FIELD-BKR DISCREP. TRIPS
0785
TACHOMETER TRIPS
0786
OFFLINE OVERCURRENT TRIPS
0787
PHASE OVERCURRENT TRIPS
0788
NEG.SEQ. OVERCURRENT TRIPS
0789
GROUND OVERCURRENT TRIPS
078A
PHASE DIFFERENTIAL TRIPS
078B
UNDERVOLTAGE TRIPS
078C
OVERVOLTAGE TRIPS
078D
VOLTS/HERTZ TRIPS
078E
PHASE REVERSAL TRIPS
078F
UNDERFREQUENCY TRIPS
0790
OVERFREQUENCY TRIPS
0791
NEUTRAL O/V (FUND) TRIPS
0792
NEUTRAL U/V (3rd) TRIPS
0793
REACTIVE POWER TRIPS
0794
REVERSE POWER TRIPS
0795
LOW FORWARD POWER TRIPS
0796
STATOR RTD TRIPS
0797
BEARING RTD TRIPS
0798
OTHER RTD TRIPS
0799
AMBIENT RTD TRIPS
079A
THERMAL MODEL TRIPS
079B
INADVERTENT ENERG. TRIPS
079C
ANALOG INPUT 1 TRIPS
079D
ANALOG INPUT 2 TRIPS
079E
ANALOG INPUT 3 TRIPS
079F
ANALOG INPUT 4 TRIPS
MAINTENANCE / GENERAL COUNTERS
07A0
NUMBER OF BREAKER OPERATIONS
1, 2, 3
See Table footnotes on page 6–39
GE Power Management
RANGE
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–52 to 251
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
–50000 to 50000
N/A
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
0 to 50000
489 Generator Management Relay
6.3 MEMORY MAP
STEP
UNITS
FORMAT
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
°F
F4
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
1
Units
F12
N/A
N/A
F18
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
1
F1
DEFAULT
–52
–52
–52
–52
–52
–52
–52
–52
–52
0
0
0
0
0
0
0
0
N/A
0
0
0
0
0
0
0
0
6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
6-17