6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (Sheet 23 of 29)
ADDR NAME
TIME TO TRIP AT 3.50 × FLA
2828
TIME TO TRIP AT 3.75 × FLA
282A
TIME TO TRIP AT 4.00 × FLA
282C
TIME TO TRIP AT 4.25 × FLA
282E
TIME TO TRIP AT 4.50 × FLA
2830
TIME TO TRIP AT 4.75 × FLA
2832
TIME TO TRIP AT 5.00 × FLA
2834
TIME TO TRIP AT 5.50 × FLA
2836
TIME TO TRIP AT 6.00 × FLA
2838
TIME TO TRIP AT 6.50 × FLA
283A
TIME TO TRIP AT 7.00 × FLA
283C
TIME TO TRIP AT 7.50 × FLA
283E
TIME TO TRIP AT 8.00 × FLA
2840
TIME TO TRIP AT 10.0 × FLA
2842
TIME TO TRIP AT 15.0 × FLA
2844
TIME TO TRIP AT 20.0 × FLA
2846
2848
MINIMUM ALLOWABLE VOLTAGE
2849
STALL CURRENT @ MIN VOLTAGE
284A
SAFE STALL TIME @ MIN VOLTAGE
284B
ACCEL. INTERSECT @ MIN VOLT
284C
STALL CURRENT @ 100% VOLTAGE
284D
SAFE STALL TIME @ 100% VOLTAGE
284E
ACCEL. INTERSECT @ 100% VOLT
THERMAL MODEL / THERMAL ELEMENTS
2900
THERMAL MODEL ALARM
2901
ASSIGN ALARM RELAYS (2-5)
2902
THERMAL ALARM LEVEL
2903
THERMAL MODEL ALARM EVENTS
2904
THERMAL MODEL TRIP
2905
ASSIGN TRIP RELAYS (1-4)
MONITORING / TRIP COUNTER
2A00
TRIP COUNTER ALARM
2A01
ASSIGN ALARM RELAYS (2-5)
2A02
TRIP COUNTER ALARM LEVEL
2A03
TRIP COUNTER ALARM EVENTS
MONITORING / BREAKER FAILURE
2A20
BREAKER FAILURE ALARM
2A21
ASSIGN ALARM RELAYS (2-5)
2A22
BREAKER FAILURE LEVEL
2A23
BREAKER FAILURE DELAY
2A24
BREAKER FAILURE ALARM EVENTS
MONITORING / TRIP COIL MONITOR
2A30
TRIP COIL MONITOR ALARM
2A31
ASSIGN ALARM RELAYS (2-5)
2A32
TRIP COIL MONITOR ALARM EVENTS
MONITORING / VT FUSE FAILURE
2A50
VT FUSE FAILURE ALARM
2A51
ASSIGN ALARM RELAYS (2-5)
2A52
VT FUSE FAILURE ALARM EVENTS
MONITORING / CURRENT DEMAND
2A60
CURRENT DEMAND PERIOD
2A61
CURRENT DEMAND ALARM
2A62
ASSIGN ALARM RELAYS (2-5)
1, 2, 3
See Table footnotes on page 6–39
GE Power Management
RANGE
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
5 to 999999
70 to 95
200 to 1500
5 to 9999
200 to 1500
200 to 1500
5 to 9999
200 to 1500
0 to 2
1 to 4
10 to 100
0 to 1
0 to 2
0 to 3
0 to 2
1 to 4
1 to 50000
0 to 1
0 to 2
1 to 4
5 to 2000
10 to 1000
0 to 1
0 to 2
1 to 4
0 to 1
0 to 2
1 to 4
0 to 1
5 to 90
0 to 2
1 to 4
489 Generator Management Relay
6.3 MEMORY MAP
STEP
UNITS
FORMAT
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
s
F10
1
%
F1
× FLA
1
F3
1
s
F2
× FLA
1
F3
× FLA
1
F3
1
s
F2
× FLA
1
F3
1
F115
1
F50
1
%Used
F1
1
F105
1
F115
1
F50
1
F115
1
F50
1
Trips
F1
1
F105
1
F115
1
F50
× CT
1
F3
10
ms
F1
1
F105
1
F115
1
F50
1
F105
1
F115
1
F50
1
F105
1
min
F1
1
A
F115
1
A
F50
DEFAULT
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
80
480
200
380
600
100
500
0
16
75
0
6
0
1
0
16
25
0
0
16
100
100
0
0
16
0
0
16
0
15
0
16
6-33