Control elements placement
Control panel is placed on the right rear mudguard.
1. Electrohydraulics control
2. External hydraulic circuit control
Outer hydraulic circuit
It delivers pressure oil for hydraulic appliances connected to the hydraulic outlets terminated by quick
couplings.
Both the rear and front coupling sockets are 12.5 mm (1/2 ') in size, only the socket 0 marked on the rear
panel of the quick release couplings has a 20 mm (3/4') width - a waste bin.
All quick couplings comply with international ISO standards.
Connecting and disconnecting quick-couplers
When connecting and disconnecting the quick-couplers pay increased attention with regard to
the residual oil that remains in the socket or on the plug of the quick-coupler. For environmental
reasons after every disconnection of quick-couplers this residual oil must be removed with any
textile material.
Quick-couplings with drip collection
On request, dripping system for holding leakage oil can be
installed. Regularly check whether the tank is not full;
dispose of the oil in an environment-friendly way.
146
HYDRAULIC SYSTEM
FHD18N063
FHD18N064