Digital Setpoint Source - Rs485 Connection, Usb To Rs485 Converter (Tescom Model #82948) - Emerson Tescom ER5000 Series User Manual

Table of Contents

Advertisement

ER5000 —
Installation Variations
Setpoint Wiring Variations
Digital Setpoint Source — RS485 Connection,
USB to RS485 Converter
(TESCOM™ Model #82948)
For most applications, the supplied USB cable provides the most
efficient connection to the PC. The controller can also be wired to
connect through an RS485 converter, as shown in Figure 28.
TDA(-)
TDB(+)
Figure 28: RS485 Connection (USB to RS485 Converter)
GREEN
BLUE
WARNING
The controller must be disconnected from the power supply before
any additional wiring or change to jumper configuration is
performed. Do not reconnect the power supply until all additional
wiring connections have been made and are properly installed.
Refer to Table 11 to verify correct wiring.
Table 11: Wiring for RS485 Connection (USB to RS485 Converter)
J3 Pins
Wire Color
Function
1
brown
+setpoint input
2
red
-setpoint input
3
orange
+feedback input
4
yellow
-feedback input
5
green
-RS485 network connection
6
blue
+RS485 network connection
7
violet
+24V DC power
8
gray
24V return (power ground)
9
white
+5V output (5 mA max.)
10
black
analog signal/board ground
11
pink
analog signal output
*
*
(active in Enhanced "F" models ONLY)
12
tan
analog signal/board ground
The USB to RS485 converter is powered through its USB
connection, so it does not require direct wiring to a power supply.