Emerson Bettis RTS FQ Series Operating Manual page 89

Fail-safe quarter-turn electric actuator
Table of Contents

Advertisement

User Instructions
MAN-02-04-60-0351-EN Rev. 3
TYPE
Max Electric Torque
End of Spring Remaining Fail-Safe Torque
Modulating Torque Rating
Fail-Safe Spring Return Direction
Fail-Safe Trigger
Electric Stroke Time Range (Field Adjustable)
Fail-Safe Spring Rate / Field Adjustable
Available Travel
Operation Mode
Manual Override
VALVE-MOUNTING
Mounting Base
Max Stem Diameter
Max Square (Flats)
OPERATING CONDITIONS
Ingress Protection
Ambient Temperature
HOUSING
Material
Enclosure
Certification
Coating
Weight Approx.
MOTOR - BRUSHLESS TECHNOLOGY
Isolation Class
Power Supply
Current Consumption
Power Comsumption idle with fail-safe brake energized
ACTUATOR CONTROL
Technology
Control Unit
Control Elements
Control Functions
Local Display
LEDs
Communication
Control
Inputs
Status
Outputs
Voltage Input and Output
Power Supply - External
Power Supply - By Actuator
FUNCTIONS
Standard
ELECTRICAL CONNECTION
Cable Entry
OPTIONS
Digital Communication
Relay Board
Analog Position Transmitter
Coating
Technical Data and Certifications
Section 17: Technical Data and Certifications
FQ-03
max. lbs. ft (Nm)
220 (300)
440 (600)
max. lbs. ft (Nm)
110 (150)
220 (300)
max. lbs. ft (Nm)
110 (150)
220 (300)
Loss of 24 V DC fail-safe command signal or main power supply (selectable)
sec
14 - 420
sec
1 - 5
On/Off Duty
Modulating Duty
ISO 5210
F07/F10
inch (mm)
1 (25.4)
inch (mm)
0.86 (22)
1ph, 24VD – CSA NEC 500 /
NEC505, ATEX, IECEx, LVD
3ph - ATEX
High quality two component polyurethane paint system-C3 ISO12944-5
lb. (kg)
77 (35)
Insulation class F, max. 155° C (311°F) permanent temperature
24 - 230 VDC / 115 - 230 VAC Single Phase / 380 - 480 VAC Three Phase
V
24 VDC (option not available with FQ-10, FQ-30, FQ-50)
A
W
Integrated processor control unit with frequency technology for variable speed control
· Pad-lockable selector switch LOCAL - OFF- REMOTE contact less sensor technology
· Control switch OPEN - STOP - CLOSE contact less sensor technology
· Language independent symbols
· Full stroke test
· Partial stroke test
Backlit LCD display, can be rotated in 90 degree increments
4 programmable red, green, blue LEDs for operation - readiness - warning - and error messages
Infrared communication interface and Bluetooth technology including Android App for simple configuration
5 configurable binary (discrete) control inputs
OPEN - STOP - CLOSE - EMERGENCY OPEN - EMERGENCY CLOSE
· Nominal voltage 24VDC
· 8 configurable binary (relay) outputs:
READY - OPEN - CLOSE - RUNNING OPEN - RUNNING CLOSE - TORQUE - LOCAL - REMOTE
· Power supply 24 VDC +/– 6V (selectable internal or external)
· Input power range: 20-30VDC max current consumption 320mA or 100mA in current save mode
· Status indication also in case of a main power supply failure
· Output voltage: typical 22V max output current 150mA
· Reference ground is the common ground of the control unit and of the analog inputs and outputs
· Switch-off mode adjustable, travel or torque dependent
· Torque adjustable: 25-100% of max torque
· Adjustable speed for process optimization and emergency speeds.
· Password protection (reading and/or writing)
· Multilingual display
· Status indication for binary inputs/outputs and analog signals on LCD display
· Data logging for analysis and service
· Motor protection by positive temperature coefficient sensors
3 metric threaded boreholes for cable grands: Weather-proof 1xM40, 1xM32, 1xM25 /
Explosion-proof 1xM40 + 2xM20
Modbus RTU, ProfiBus, ProfiNet, Foundation FieldBus HART Platforms
250 VAC, 2A with 4 outputs
0/4-20mA (2-wire)
4 layer with Epoxy under coat for increased corrosion protection – C5-I, C5-M ISO12944-5
FQ-06
FQ-10
FQ-20
738 (1000)
1475 (2000) 2210 (3000) 3687 (5000)
369 (500)
730 (1000)
369 (500)
730 (1000)
Selectable (CW or CCW) spring return
14 - 420
20 - 500
30 - 850
1 - 5
1 - 5
3 - 10
90 +/– 5° with mechanical end-stop
S2
S9
Optional
F10/F12
F12/F14
F14/F16
1.57 (40)
1.92 (49)
2.36 (60)
1.25 (32)
1.61 (41)
1.88 (48)
IP66 (NEMA 4x) , IP67 (NEMA 6), IP68
- 40° C (-40°F) to +60°C (140°F)
Aluminum
Weather-proof / Explosion-proof (optional)
1ph, 24VD – CSA NEC 505, ATEX
117 (53)
229 (104)
311 (141)
2.5
40
Febraury 2019
FQ-30
FQ-50
1100 (1500) 1800 (2500)
1100 (1500) 1800 (2500)
38 - 1050
60 - 1600
3 - 10
6 - 15
F14/F16
F16/F25
2.36 (60)
2.95 (75)
1.88 (48)
(55)
450 (204)
754 (342)
84

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents